Literature DB >> 16206174

Therapeutic plasma exchange performed in tandem with hemodialysis for patients with M-protein disorders.

Aftab Mahmood1, Donata Sodano, Anthony Dash, Robert Weinstein.   

Abstract

M-proteins are monoclonal immunoglobulins or immunoglobulin fragments that aberrantly accumulate in the plasma. Hemodialysis (HD) patients with M-proteins may, under certain circumstances, also need therapeutic plasma exchange (TPE). We employed a protocol for tandem TPE/HD in patients with M-protein disorders. We followed the urea reduction ratio (URR), a measure of the efficiency of HD, to compare the effect of TPE on HD efficiency during tandem procedures versus the efficiency of HD performed as a stand-alone procedure in the same patients. Three men (J.M., R.T., M.M.) underwent 23, 80, and 25 tandem TPE/HD over 3, 17, and 7 months, respectively, almost all in the outpatient setting. Mean whole blood flow rate (in ml/min) was slower during hemodialysis alone than during TPE/HD for J.M. (289 +/- 24 vs. 332 +/- 22, P < 0.0001) and R.T. (310 +/- 20 vs. 367 +/- 15, P < 0.0001) but not for M.M. (395 +/- 65 vs. 404 +/- 62, P = 0.6844). URR was equivalent during hemodialysis alone and during TPE/HD for J.M. (54 +/- 4.2 vs. 58 +/- 1.4, P = 0.3333), R.T. (69 +/- 4.9 vs. 70 +/- 2.5, P = 0.9804), and M.M. (71 +/- 2.4 vs. 67 +/- 1.5, P = 0.1143). J.M.'s renal function recovered sufficiently to permit discontinuation of hemodialysis. R.T. experienced both subjective and objective improvement of his arthritic symptoms. M.M. achieved hemostatic control but ultimately died of amyloidosis. TPE/HD is feasible using disparate pieces of equipment when the therapeutic plasma exchange circuit is connected in parallel with the low-pressure side of the hemodialysis circuit. Our experience illustrates that therapeutic plasma exchange did not adversely impact hemodialysis when the two procedures were performed in tandem.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16206174     DOI: 10.1002/jca.20068

Source DB:  PubMed          Journal:  J Clin Apher        ISSN: 0733-2459            Impact factor:   2.821


  4 in total

Review 1.  Tandem hemodialysis and plasma exchange.

Authors:  Guido Filler; William F Clark; Shih-Han S Huang
Journal:  Pediatr Nephrol       Date:  2013-09-11       Impact factor: 3.714

2.  Tandem plasma-exchange and haemodialysis in a paediatric dialysis unit.

Authors:  Fabio Paglialonga; Gianluigi Ardissino; Antonietta Biasuzzi; Sara Testa; Alberto Edefonti
Journal:  Pediatr Nephrol       Date:  2011-12-02       Impact factor: 3.714

3.  Safety and efficacy of tandem hemodialysis and plasma exchange in children.

Authors:  Betti Schaefer; Akos Ujszaszi; Susanne Schaefer; Karl Heinz Heckert; Franz Schaefer; Claus Peter Schmitt
Journal:  Clin J Am Soc Nephrol       Date:  2014-07-03       Impact factor: 8.237

4.  Atypical rapid progression of osteoarticular amyloidosis involving the hip in a patient on hemodialysis using polyacrylonitrile membranes.

Authors:  Kenneth S Lee; Marnix T van Holsbeeck; Alexander Abbud
Journal:  Skeletal Radiol       Date:  2010-01       Impact factor: 2.199

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.