Literature DB >> 16206139

The effect of alkylamine additives on the sensitivity of detection for paclitaxel and docetaxel and analysis in plasma of paclitaxel by liquid chromatography-tandem mass spectrometry.

Songmei Gao1, Zong-Ping Zhang, L E Edinboro, Lambert C Ngoka, H T Karnes.   

Abstract

The formation of multiple molecular ions, especially due to sodium adduct ion formation, is commonly observed in electrospray mass spectrometry and may make reproducible and sensitive quantitation difficult. The objective of this work was to investigate the underlying mechanism involved in the suppression of multiple molecular ion formation and to improve the sensitivity of detection for the two anti-neoplastic agents paclitaxel and docetaxel. The results showed that alkylamine additives could significantly improve the detection of paclitaxel and docetaxel by suppression of multiple molecular ions through preferential formation of a predominant alkylamine adduct ion. Possible binding sites, binding interactions and binding competition were investigated for the sodium adduct and alkylamine adduct ions using various experimental techniques. The formation of a predominant amine adduct ion may be due to increased surface activity in the droplet. The optimal alkylamine for both analytes was octylamine, which increased peak heights of paclitaxel and docetaxel 4.8 and 3.7-fold (n = 3), respectively. The precision of the signals for the analytes was also improved 5.7-fold. A quantitative assay in plasma for paclitaxel was partially validated for the calibration range 1.0-1000 ng/mL (r = 0.9977) when using 0.05% octylamine as a reconstitution solution additive. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.5 and 0.9 ng/mL, respectively. Acceptable precision, accuracy, specificity and sample stability were demonstrated for this assay. This approach may prove useful for other analytes with similar binding sites. Copyright 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16206139     DOI: 10.1002/bmc.582

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column.

Authors:  Mariëtte T Ackermans
Journal:  Pract Lab Med       Date:  2021-09-01

2.  A new high-performance liquid chromatography-tandem mass spectrometry method for the determination of paclitaxel and 6α-hydroxy-paclitaxel in human plasma: Development, validation and application in a clinical pharmacokinetic study.

Authors:  Bianca Posocco; Mauro Buzzo; Andrea Follegot; Luciana Giodini; Roberto Sorio; Elena Marangon; Giuseppe Toffoli
Journal:  PLoS One       Date:  2018-02-23       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.