Literature DB >> 16204719

Generation of parametric image of regional myocardial blood flow using H(2)(15)O dynamic PET and a linear least-squares method.

Jae Sung Lee1, Dong Soo Lee, Ji Young Ahn, Jeong Seok Yeo, Gi Jeong Cheon, Seok-Ki Kim, Kwang Suk Park, June-Key Chung, Myung Chul Lee.   

Abstract

UNLABELLED: Although a parametric image of myocardial blood flow (MBF) can be obtained from H(2)(15)O PET using factor and cluster analysis, this approach is limited when factor analysis fails to extract each cardiac component. In this study, a linear least-squares (LLS) method for estimating MBF and generating a MBF parametric image was developed to overcome this limitation. The computer simulation was performed to investigate the statistical properties of the LLS method, and MBF values obtained from the MBF parametric images in dogs were compared with those obtained using the conventional region of interest (ROI) and invasive microsphere methods.
METHODS: A differential model equation for H(2)(15)O in the myocardium was modified to incorporate the partial-volume and spillover effect. The equation was integrated from time 0 to each PET sampling point to obtain a linearlized H(2)(15)O model equation. The LLS solution of this equation was estimated and used to calculate the MBF, the perfusable tissue fraction (PTF), and the arterial blood volume fraction (V(a)). A computer simulation was performed using the input function obtained from canine experiments and the tissue time-activity curves contaminated by various levels of Poisson noise. The parametric image of the MBF, PTF, and V(a) was constructed using the PET data from dogs (n = 7) at rest and after pharmacologic stress. The regional MBF from the parametric image was compared with those produced by the ROI method using a nonlinear least-squares (NLS) estimation and an invasive radiolabeled microsphere technique.
RESULTS: The simulation study showed that the LLS method was better than the NLS method in terms of statistical reliability, and the parametric images of the MBF, PTF, and V(a) using the LLS method had good image quality and contrast. The regional MBF values using the parametric image showed a good correlation with those using the ROI method (y = 0.84x + 0.40; r = 0.99) and the microsphere technique (y = 0.95x + 0.29; r = 0.96). The computation time was approximately 10 s for the 32 x 32 x 6 x18 (pixel x pixel x plane x frame) matrix.
CONCLUSION: A noninvasive, very fast, and accurate method for estimating the MBF and generating a MBF parametric image was developed using the LLS estimation technique and H(2)(15)O dynamic myocardial PET.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16204719

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

1.  Comparative assessment of parametric neuroreceptor mapping approaches based on the simplified reference tissue model using [¹¹C]ABP688 PET.

Authors:  Seongho Seo; Su J Kim; Yu K Kim; Jee-Young Lee; Jae M Jeong; Dong S Lee; Jae S Lee
Journal:  J Cereb Blood Flow Metab       Date:  2015-08-05       Impact factor: 6.200

Review 2.  Methodology for quantifying absolute myocardial perfusion with PET and SPECT.

Authors:  Martin A Lodge; Frank M Bengel
Journal:  Curr Cardiol Rep       Date:  2007-04       Impact factor: 2.931

3.  Assessment of myocardial perfusion by dynamic O-15-labeled water PET imaging: validation of a new fast factor analysis.

Authors:  Itaru Adachi; Oliver Gaemperli; Ines Valenta; Tiziano Schepis; Patrick T Siegrist; Valerie Treyer; Cyrill Burger; Koichi Morita; Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

Review 4.  Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses.

Authors:  Seongho Seo; Su Jin Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Neurosci Bull       Date:  2014-09-28       Impact factor: 5.203

Review 5.  KSNM60 in Cardiology: Regrowth After a Long Pause.

Authors:  Sang-Geon Cho; Eun Jung Kong; Won Jun Kang; Jin Chul Paeng; Hee-Seung Henry Bom; Ihnho Cho
Journal:  Nucl Med Mol Imaging       Date:  2021-06-08

6.  Multiple linear analysis methods for the quantification of irreversibly binding radiotracers.

Authors:  Su Jin Kim; Jae Sung Lee; Yu Kyeong Kim; James Frost; Gary Wand; Mary E McCaul; Dong Soo Lee
Journal:  J Cereb Blood Flow Metab       Date:  2008-07-16       Impact factor: 6.200

7.  Comparative evaluation of the algorithms for parametric mapping of the novel myocardial PET imaging agent 18F-FPTP.

Authors:  Ji Who Kim; Seongho Seo; Hyeon Sik Kim; Dong-Yeon Kim; Ho-Young Lee; Keon Wook Kang; Dong Soo Lee; Hee-Seung Bom; Jung-Joon Min; Jae Sung Lee
Journal:  Ann Nucl Med       Date:  2017-04-25       Impact factor: 2.668

8.  Multimodality quantitative assessments of myocardial perfusion using dynamic contrast enhanced magnetic resonance and 15O-labelled water positron emission tomography imaging.

Authors:  G Papanastasiou; M C Williams; M R Dweck; S Mirsadraee; N Weir; A Fletcher; C Lucatelli; D Patel; E J R van Beek; D E Newby; S I K Semple
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-01-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.