Literature DB >> 1620304

Experimental evaluation of a collagen-coated vicryl mesh as a dural substitute.

F San-Galli1, V Darrouzet, J Rivel, C Baquey, D Ducassou, J Guérin.   

Abstract

Dural substitutes must provide immediate restitution of a membranous covering for the brain without inducing any adverse reaction in the host or provoking adhesions to underlying nervous tissues. Ideally, the material should disappear completely and be replaced by tissues similar to the dura mater. In this study, parietal dural defects were created in 12 beagle dogs and closed with a vicryl mesh prosthesis made watertight by a film of bovine collagen. Clinical and biological tolerances were satisfactory. There was one case of early local infection. Gross and microscopic examinations performed between 7 days and 9 months after implantation showed degradation of the prosthetic mesh and connective tissue growth into the implant mimicking dura mater as early as 15 days after implantation. There was no attendant inflammatory reaction or cortical adhesions or other adverse reactions. The authors conclude that collagen-embedded vicryl mesh provides satisfactory biological function and compatibility when used as a substitute for dura mater in the dog.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1620304     DOI: 10.1227/00006123-199203000-00014

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  5 in total

1.  Artificial dural sealant that allows multiple penetrations of implantable brain probes.

Authors:  Nathan Jackson; Jit Muthuswamy
Journal:  J Neurosci Methods       Date:  2008-03-18       Impact factor: 2.390

2.  Complications to the use of vicryl-collagen dural substitute.

Authors:  G Gudmundsson; I Søgaard
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

3.  Evaluation of efficacy and biocompatibility of a novel semisynthetic collagen matrix as a dural onlay graft in a large animal model.

Authors:  Axel Neulen; Angelika Gutenberg; Ildikó Takács; György Wéber; Jürgen Wegmann; Walter Schulz-Schaeffer; Alf Giese
Journal:  Acta Neurochir (Wien)       Date:  2011-07-09       Impact factor: 2.216

4.  Clinical experience with a novel bovine collagen dura mater substitute.

Authors:  Bruno Silva Costa; George de Albuquerque Cavalcanti-Mendes; Marcelo Sartori de Abreu; Atos Alves de Sousa
Journal:  Asian J Neurosurg       Date:  2010-07

5.  Hydrogel-mesh composite for wound closure.

Authors:  Yang Gao; Xiuyuan Han; Jiaojiao Chen; Yudong Pan; Meng Yang; Linhe Lu; Jian Yang; Zhigang Suo; Tongqing Lu
Journal:  Proc Natl Acad Sci U S A       Date:  2021-07-13       Impact factor: 11.205

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.