Literature DB >> 16202870

Disposable polydimethylsiloxane/silicon hybrid chips for protein detection.

Shifeng Li1, Pierre N Floriano, Nicolaos Christodoulides, David Y Fozdar, Dongbing Shao, Mehnaaz F Ali, Priya Dharshan, Sanghamitra Mohanty, Dean Neikirk, John T McDevitt, Shaochen Chen.   

Abstract

This paper presents disposable protein analysis chips with single- or four-chamber-constructed from poly(dimethylsiloxane) (PDMS) and silicon. The chips are composed of a multilayer stack of PDMS layers that sandwich a silicon microchip. This inner silicon chip features an etched array of micro-cavities hosting polymeric beads. The sample is introduced into the fluid network through the top PDMS layer, where it is directed to the bead chamber. After reaction of the analyte with the probe beads, the signal generated on the beads is captured with a CCD camera, digitally processed, and analyzed. An established bead-based fluorescent assay for C-reactive protein (CRP) was used here to characterize these hybrid chips. The detection limit of the single-chamber protein chip was found to be 1 ng/ml. Additionally, using a back pressure compensation method, the signals from each chamber of the four-chamber chip were found to fall within 10% of each other.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16202870     DOI: 10.1016/j.bios.2004.12.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Current developments in salivary diagnostics.

Authors:  Craig S Miller; Joseph D Foley; Alison L Bailey; Charles L Campell; Roger L Humphries; Nicolaos Christodoulides; Pierre N Floriano; Glennon Simmons; Bryon Bhagwandin; James W Jacobson; Spencer W Redding; Jeffrey L Ebersole; John T McDevitt
Journal:  Biomark Med       Date:  2010-02       Impact factor: 2.851

2.  A disposable bio-nano-chip using agarose beads for high performance immunoassays.

Authors:  Nan Du; Jie Chou; Eliona Kulla; Pierre N Floriano; Nicolaos Christodoulides; John T McDevitt
Journal:  Biosens Bioelectron       Date:  2011-07-23       Impact factor: 10.618

3.  Finger-actuated, self-contained immunoassay cassettes.

Authors:  Xianbo Qiu; Jason A Thompson; Zongyuan Chen; Changchun Liu; Dafeng Chen; Sudhir Ramprasad; Michael G Mauk; Serge Ongagna; Cheryl Barber; William R Abrams; Daniel Malamud; Paul L A M Corstjens; Haim H Bau
Journal:  Biomed Microdevices       Date:  2009-12       Impact factor: 2.838

Review 4.  Diagnoses Based on C-Reactive Protein Point-of-Care Tests.

Authors:  Miroslav Pohanka
Journal:  Biosensors (Basel)       Date:  2022-05-17

5.  Single bead-based electrochemical biosensor.

Authors:  Changchun Liu; Michael G Schrlau; Haim H Bau
Journal:  Biosens Bioelectron       Date:  2009-08-28       Impact factor: 10.618

6.  Micro-mirrors for nanoscale three-dimensional microscopy.

Authors:  Kevin Seale; Chris Janetopoulos; John Wikswo
Journal:  ACS Nano       Date:  2009-03-24       Impact factor: 15.881

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.