Literature DB >> 16201902

Preliminary evaluation of the performance of a new, highly sensitive commercial immunoassay for serum ferritin determination.

Paolo Signò1, Alessandra Barassi, Raffaele Novario, Gian Vico Melzi d'Eril.   

Abstract

We evaluated the analytical performance of a new, commercial, fully automated immunoturbidimetric assay for the determination of ferritin [FER-Latex(X2)CN SEIKEN, Denka Seiken, Japan] in serum on the Olympus AU2700 analyzer. The new assay is a latex-enhanced turbidimetric immunoassay with an analysis time of 10 min. The linearity of the assay was confirmed up to 2505 pmol/L (R2=0.999). The detection limit and the functional sensitivity were both 4.5 pmol/L. The intra- and inter-assay imprecision (CV) at 67, 506, 2186 pmol/L was < 1.8% and < 2.5%, respectively. Verification of the traceability to a WHO standard (80/578) showed a recovery of 102.6% (target value 449 pmol/L). No hook effect was observed in samples containing up to 33,705 pmol/L. The assay showed good correlation with the Beckman Immage nephelometric system (r=0.999). Hemoglobin (< or = 9.8 g/L), total bilirubin (< or = 113 micromol/L), conjugated bilirubin (< or = 109 micromol/L) and rheumatoid factor (< or = 5.2x10(5) IU/L) did not interfere with the assay. The reference interval (2.5-97.5 percentile) was 72-521 pmol/L for men and 27-267 pmol/L for women. The reference interval in patients with anemia, malignant tumors and hemochromatosis was 5.6-52, 130-2436 and 1465-2903 pmol/L, respectively. On the basis of the receiver operating characteristic curve, the 90% sensitivity cut-off value to distinguish between patients with and without iron deficiency was 40 pmol/L. The new latex turbidimetric procedure for ferritin assay is an attractive alternative that avoids the need for dedicated instrumentation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16201902     DOI: 10.1515/CCLM.2005.149

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  2 in total

1.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

Review 2.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.