Literature DB >> 16200661

Uncertainty of inductively coupled plasma mass spectrometry based measurements: an application to the analysis of urinary barium, cesium, antimony and tungsten.

A Alimonti1, G Forte, S Spezia, A Gatti, G Mincione, A Ronchi, P Bavazzano, B Bocca, C Minoia.   

Abstract

The wide use of barium (Ba), cesium (Cs), antimony (Sb) and tungsten (W) in many industrial and agricultural fields causes the increased release of these metals into the environment, laying the basis for health risk. To assess the exposure for the general population, the development of adequate and reliable analytical techniques becomes compulsory. This study refers to the quantification of urinary Ba, Cs, Sb and W levels by both quadrupole (Q) and sector field (SF) inductively coupled plasma mass spectrometry (ICP-MS). The two procedures were compared for their performances and their measurement uncertainties. The limits of detection were (Q and SF) 23.0 and 5.21 ng L(-1) for Ba; 21.1 and 7.52 ng L(-1) for Cs; 1.09 and 0.43 ng L(-1) for Sb; and 0.36 and 0.49 ng L(-1) for W. The trueness was better than 93.3% and the precision less than 12% for both techniques. Relative expanded uncertainties of the analytical procedures, at the median levels found in the general population, were below 5% for all the elements with both ICP-MS techniques. The uncertainties related to the calibration and repeatability were the parameters most influencing the final analytical performance. The urinary median values observed in healthy subjects from central Italy were 1146, 4301, 60.8 and 48.5 ng L(-1) for Ba, Cs, Sb and W, respectively. (c) 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16200661     DOI: 10.1002/rcm.2180

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Cesium chloride-induced torsades de pointes.

Authors:  Matthew Wiens; Wendy Gordon; Daisy Baulcomb; Andre Mattman; Tom Mock; Robert Brown
Journal:  Can J Cardiol       Date:  2009-09       Impact factor: 5.223

2.  A highly Sensitive Turn-on Fluorescent Sensor for Ba2+ Based on G-Quadruplexes.

Authors:  Lijun Xu; Yang Chen; Ruihua Zhang; Tian Gao; Yajie Zhang; Xiaoqiang Shen; Renjun Pei
Journal:  J Fluoresc       Date:  2016-11-18       Impact factor: 2.217

3.  The exposure to and health effects of antimony.

Authors:  Ross G Cooper; Adrian P Harrison
Journal:  Indian J Occup Environ Med       Date:  2009-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.