Literature DB >> 16198505

Use of CT simulation for treatment of cervical cancer to assess the adequacy of lymph node coverage of conventional pelvic fields based on bony landmarks.

Marisa H Finlay1, Ida Ackerman, Romeo G Tirona, Paul Hamilton, Lisa Barbera, Gillian Thomas.   

Abstract

PURPOSE: To assess the adequacy of nodal coverage of "conventional" pelvic radiation fields for carcinoma of the cervix, with contoured pelvic vessels on simulation computed tomography (CT) as surrogates for lymph node location. METHODS AND MATERIALS: Pelvic arteries were contoured on non-contrast-enhanced CT simulation images of 43 patients with cervix cancer, FIGO Stages I-III. Vessel contours were hidden, and conventional pelvic fields were outlined: (1) anterior/posterior fields (AP): superior border, L5-S1 interspace; inferior border, obturator foramina; lateral border, 2 centimeters lateral to pelvic brim. (2) Lateral fields (LAT): Anterior border, symphysis pubis; posterior border, S2-S3 interspace. Distances were measured between the following: (1) bifurcation of the common iliac artery and superior border, (2) external iliac artery and lateral border of the AP field, and (3) external iliac artery and anterior border of the LAT field. The distances were considered as "inadequate" if <15 mm, "adequate" if 15-20 mm, and "generous" if >20 mm.
RESULTS: Superiorly, 34 patients (79.1%) had inadequate coverage. On the AP, margins were generous in 19 (44.2%), but inadequate in 9 (20.9%). On the LAT, margins were inadequate in 30 (69.8%) patients. Overall, 41 (95.4%, CI, 84.2%-99.4%) patients had at least 1 inadequate margin, the majority located superiorly. Twenty-four (55.8%; CI, 39.9%-70.9%) patients had at least 1 generous margin, the majority located laterally on the AP field.
CONCLUSION: Conventional pelvic fields based on bony landmarks do not provide optimal lymph node coverage in a substantial proportion of patients and may include excess normal tissue in some. CT simulation with vessel contouring as a surrogate for lymph node localization provides more precise and individualized field delineation.

Entities:  

Mesh:

Year:  2005        PMID: 16198505     DOI: 10.1016/j.ijrobp.2005.06.025

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

Review 1.  The role of imaging in the management of non-metastatic cervical cancer.

Authors:  Orit Kaidar-Person; Roxolyana Bortnyak-Abdah; Amnon Amit; Alison Berniger; Rahamim Ben-Yosef; Abraham Kuten
Journal:  Med Oncol       Date:  2012-04-25       Impact factor: 3.064

2.  Evaluation of pelvic lymph node coverage of conventional radiotherapy fields based on bony landmarks in Chinese cervical cancer patients using CT simulation.

Authors:  Xiang Zhang; Hua Yu
Journal:  J Zhejiang Univ Sci B       Date:  2009-09       Impact factor: 3.066

3.  Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer.

Authors:  Susan Guo; Ronald D Ennis; Stephen Bhatia; Frieda Trichter; Benjamin Bashist; Jinesh Shah; Manjeet Chadha
Journal:  Radiat Oncol       Date:  2010-06-27       Impact factor: 3.481

4.  Intensity Modulated Radiation Therapy and Image-Guided Adapted Brachytherapy for Cervix Cancer.

Authors:  Alexander J Lin; Elizabeth Kidd; Farrokh Dehdashti; Barry A Siegel; Sasa Mutic; Premal H Thaker; Leslie S Massad; Matthew A Powell; David G Mutch; Stephanie Markovina; Julie Schwarz; Perry W Grigsby
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-11-14       Impact factor: 7.038

5.  Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy in postoperative treatment of endometrial and cervical cancer.

Authors:  William Small; Loren K Mell; Penny Anderson; Carien Creutzberg; Jennifer De Los Santos; David Gaffney; Anuja Jhingran; Lorraine Portelance; Tracey Schefter; Revathy Iyer; Mahesh Varia; Kathryn Winter; Arno J Mundt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-26       Impact factor: 7.038

6.  Significant impact on the oncologic outcomes with intensity modulated radiotherapy and conformational radiotherapy over conventional radiotherapy in cervix cancer patients treated with radiotherapy.

Authors:  Gustavo Arruda Viani; Fred Muller Dos Santos; Juliana Fernandes Pavoni
Journal:  Rep Pract Oncol Radiother       Date:  2020-06-07

7.  Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?

Authors:  Jyotirup Goswami; Niladri B Patra; Biplab Sarkar; Ayan Basu; Santanu Pal
Journal:  South Asian J Cancer       Date:  2013-07

8.  CT Simulation to Evaluate of Pelvic Lymph Node Coverage in Conventional Radiotherapy Fields Based on Bone and Vessels Landmarks in Prostate Cancer Patients.

Authors:  Amir Shahram Yousefi Kashi; Samira Khaledi; Mohammad Houshyari
Journal:  Iran J Cancer Prev       Date:  2016-06-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.