Literature DB >> 16198102

Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode.

Meral Topçu Sulak1, Ozlem Gökdoğan, Ahmet Gülce, Handan Gülce.   

Abstract

The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinylferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method for the immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer, PVF, and the gold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential, the thickness of the polymeric film, the amount of the immobilized enzyme, pH, the amount of the deposited Au, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16198102     DOI: 10.1016/j.bios.2005.08.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Direct Electron Transfer of Hemoglobin on Manganese III Oxide-Ag Nanofibers Modified Glassy Carbon Electrode.

Authors:  Masoud Negahdary; Gholamreza Mazaheri; Somyyeh Rad; Mohammadreza Hadi; Roya Malekzadeh; Mohammad Mahdi Saadatmand; Saeed Rezaei-Zarchi; Fariba Pishbin; Mojdeh Khosravian-Hemami
Journal:  Int J Anal Chem       Date:  2012-04-05       Impact factor: 1.885

2.  Characteristics of polysilicon wire glucose sensors with a surface modified by silica nanoparticles/γ-APTES nanocomposite.

Authors:  Jing-Jenn Lin; Po-Yen Hsu; You-Lin Wu; Jheng-Jia Jhuang
Journal:  Sensors (Basel)       Date:  2011-03-02       Impact factor: 3.576

3.  Electrochemical Investigation of oligonucleotide-DNA hybridization on poly(4-methoxyphenethylamine).

Authors:  Francielle B Silva; Sabrina N Vieira; Luiz R Goulart; Julien F C Boodts; Ana G Brito-Madurro; João M Madurro
Journal:  Int J Mol Sci       Date:  2008-07-08       Impact factor: 6.208

Review 4.  Recent Advances in Applications of Voltammetric Sensors Modified with Ferrocene and Its Derivatives.

Authors:  Hadi Beitollahi; Mohammad A Khalilzadeh; Somayeh Tajik; Mohadeseh Safaei; Kaiqiang Zhang; Ho Won Jang; Mohammadreza Shokouhimehr
Journal:  ACS Omega       Date:  2020-01-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.