Literature DB >> 16198051

Determination of lead and nickel in environmental samples by flame atomic absorption spectrometry after column solid-phase extraction on Ambersorb-572 with EDTA.

Sitki Baytak1, A Rehber Türker.   

Abstract

Lead and nickel were preconcentrated as their ethylenediaminetetraacedic acid (EDTA) complexes from aqueous sample solutions using a column containing Ambersorb-572 and determined by flame atomic absorption spectrometry (FAAS). pH values, amount of solid phase, elution solution and flow rate of sample solution have been optimized in order to obtain quantitative recovery of the analytes. The effect of interfering ions on the recovery of the analytes has also been investigated. The recoveries of Pb and Ni under the optimum conditions were 99 +/- 2 and 97 +/- 3%, respectively, at 95% confidence level. Seventy-five-fold (using 750 mL of sample solution and 10 mL of eluent) and 50-fold (using 500 mL of sample solution and 10 mL of eluent) preconcentration was obtained for Pb and Ni, respectively. Time of analysis is about 4.5 h (for obtaining enrichment factor of 75). By applying these enrichment factors, the analytical detection limits of Pb and Ni were found as 3.65 and 1.42 ng mL(-1), respectively. The capacity of the sorbent was found as 0.17 and 0.21 mmol g(-1) for Pb and Ni, respectively. The interferences of some cations, such as Mn2+, Co2+, Fe3+, Al3+, Zn2+, Cd2+, Ca2+, Mg2+, K+ and Na+ usually present in water samples were also studied. This procedure was applied to the determination of lead and nickel in parsley, green onion, sea water and waste water samples. The accuracy of the procedure was checked by determining Pb and Ni in standard reference tea leaves sample (GBW-07605). The results demonstrated good agreement with the certified values.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16198051     DOI: 10.1016/j.jhazmat.2005.08.019

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  5 in total

1.  Synthesis of graphene oxide-based poly(p-aminophenol) composite and its application in solid phase extraction of trace amount of Ni(II) from aquatic samples.

Authors:  Mohammadjavad Hosseinnia Kojidi; Alireza Aliakbar
Journal:  Environ Monit Assess       Date:  2019-02-08       Impact factor: 2.513

2.  Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base.

Authors:  Berrin Topuz; Mustafa Macit
Journal:  Environ Monit Assess       Date:  2010-03-18       Impact factor: 2.513

3.  Solid Phase Extraction of Trace Elements in Waterand Tissue Samples on a Mini Column with Diphenylcarbazone Impregnated Nano-TiO2 and Their Determination by Inductively Coupled Plasma Optical Emission Spectrometry.

Authors:  Sıtkı Baytak; Zikri Arslan
Journal:  Clean (Weinh)       Date:  2015-06-01       Impact factor: 1.770

4.  Lead contamination in selected foods from Riyadh city market and estimation of the daily intake.

Authors:  Zeid A Al Othman
Journal:  Molecules       Date:  2010-10-25       Impact factor: 4.411

5.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.