Literature DB >> 16197955

Effect-directed analysis by high-performance liquid chromatography with gas-segmented enzyme inhibition.

Susanne Fabel1, Reinhard Niessner, Michael G Weller.   

Abstract

A reversed-phase high-performance liquid chromatography system with UV-detector was equipped with an on-line acetylcholinesterase inhibition assay to achieve effect-directed analysis of potentially toxic samples. The enzyme activity was detected colorimetrically using Ellman's reagent. The inhibition and substrate conversion took place in glass capillaries at a 100 microL/min flow rate. Extra-column band spreading in the reaction coils reduces the sensitivity and separation power of biochemical detectors severely. Knitted reactors exhibited no reduction of longitudinal dispersion in the tested flow range. The implementation of air-segmentation allowed an extended inhibition and substrate conversion time without a significant loss of chromatographic resolution. The limit of detection of two model compounds carbofuran (carbamate) and paraoxon-ethyl (organophosphate) was determined to be 13 ng (injected mass) and 7.4 ng, respectively, applying an isocratic chromatography method. A mixture of five insecticides was separated by a gradient elution and the inhibitory effect on the enzyme activity could be detected with high resolution. The band width at half height of the enzyme inhibition detector signal after a reaction time of about 8 min or 4.2 m of capillary, respectively, increased only by a factor of 1.4 compared to the UV-detector signal.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16197955     DOI: 10.1016/j.chroma.2005.08.081

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Three-dimensional manganese cobaltate: a highly conductive electrocatalyst for paraoxon-ethyl detection.

Authors:  Thangavelu Kokulnathan; Tzyy-Jiann Wang; Ying-Yu Wang; Varadaraj Suvina; Faheem Ahmed
Journal:  Mikrochim Acta       Date:  2022-08-04       Impact factor: 6.408

2.  A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques.

Authors:  Michael G Weller
Journal:  Sensors (Basel)       Date:  2012-07-04       Impact factor: 3.576

Review 3.  Advances in mass spectrometry-based post-column bioaffinity profiling of mixtures.

Authors:  Jeroen Kool; Martin Giera; Hubertus Irth; Wilfried M A Niessen
Journal:  Anal Bioanal Chem       Date:  2010-11-24       Impact factor: 4.142

Review 4.  Development of on-line high performance liquid chromatography (HPLC)-biochemical detection methods as tools in the identification of bioactives.

Authors:  Christiaan J Malherbe; Dalene De Beer; Elizabeth Joubert
Journal:  Int J Mol Sci       Date:  2012-03-07       Impact factor: 6.208

Review 5.  Immunoassays and biosensors for the detection of cyanobacterial toxins in water.

Authors:  Michael G Weller
Journal:  Sensors (Basel)       Date:  2013-11-05       Impact factor: 3.576

  5 in total