BACKGROUND: Guanidinoacetate (GAA) and creatine (Cr) are reliable biochemical markers of primary creatine disorders. The aim of this study was to develop and validate a method for the determination of GAA and Cr in dried blood spot through the use of stable isotope dilution and flow injection analysis (FIA)-ESI-MS/MS. METHODS: Dried blood spots were extracted using methanol-water solution containing D3-Cr. After evaporation and formation of butyl esters, samples were analyzed using multiple reaction monitoring mode (m/z 174.2-->101.1 for GAA, 188.3-->90.1 for Cr and 191.3-->93.1 for D3-Cr). RESULTS: The analysis was very fast (1 min). The detection limits were 0.34 micromol/l of blood and 0.30 micromol/l of blood for Cr and GAA, respectively, and the response was linear over the range 0.25-12.5 micromol/l of blood for GAA and 3.57-624.7 micromol/l of blood for Cr. Recovery range was 93-101% for Cr and 94-105% for GAA and between-run CVs were 5.3% for GAA and 4.5% for Cr. Ion suppression effect was also studied. The method was applied to spots obtained from two patients affected by GAMT deficiency, four patients affected by AGAT deficiency (including a newborn) as well as 282 healthy subjects. CONCLUSIONS: The detection of GAA in dried blood spot by FIA-ESI-MS/MS is a highly reliable and high throughput method for the diagnosis of GAMT and AGAT deficiencies and a possible tool for newborn screening of both these tractable disorders.
BACKGROUND:Guanidinoacetate (GAA) and creatine (Cr) are reliable biochemical markers of primary creatine disorders. The aim of this study was to develop and validate a method for the determination of GAA and Cr in dried blood spot through the use of stable isotope dilution and flow injection analysis (FIA)-ESI-MS/MS. METHODS: Dried blood spots were extracted using methanol-water solution containing D3-Cr. After evaporation and formation of butyl esters, samples were analyzed using multiple reaction monitoring mode (m/z 174.2-->101.1 for GAA, 188.3-->90.1 for Cr and 191.3-->93.1 for D3-Cr). RESULTS: The analysis was very fast (1 min). The detection limits were 0.34 micromol/l of blood and 0.30 micromol/l of blood for Cr and GAA, respectively, and the response was linear over the range 0.25-12.5 micromol/l of blood for GAA and 3.57-624.7 micromol/l of blood for Cr. Recovery range was 93-101% for Cr and 94-105% for GAA and between-run CVs were 5.3% for GAA and 4.5% for Cr. Ion suppression effect was also studied. The method was applied to spots obtained from two patients affected by GAMT deficiency, four patients affected by AGAT deficiency (including a newborn) as well as 282 healthy subjects. CONCLUSIONS: The detection of GAA in dried blood spot by FIA-ESI-MS/MS is a highly reliable and high throughput method for the diagnosis of GAMT and AGAT deficiencies and a possible tool for newborn screening of both these tractable disorders.
Authors: Kobus Herbst; Matthew Law; Pascal Geldsetzer; Frank Tanser; Guy Harling; Till Bärnighausen Journal: Curr Opin HIV AIDS Date: 2015-11 Impact factor: 4.283
Authors: Roselia Maria Spanevello; Angela Terezinha de Souza Wyse; Cinthia Melazzo Mazzanti; Roberta Schmatz; Naiara Stefanello; Jamile Fabbrin Gonçalves; Margarete Bagatini; Vanessa Battisti; Vera Maria Morsch; Maria Rosa Chitolina Schetinger Journal: Neurochem Res Date: 2008-02-07 Impact factor: 3.996
Authors: J Daniel Sharer; Olaf Bodamer; Nicola Longo; Silvia Tortorelli; Mirjam M C Wamelink; Sarah Young Journal: Genet Med Date: 2017-01-05 Impact factor: 8.822
Authors: Tom van der Laan; Anne-Charlotte Dubbelman; Kevin Duisters; Alida Kindt; Amy C Harms; Thomas Hankemeier Journal: Anal Chem Date: 2020-10-15 Impact factor: 6.986