Literature DB >> 16196293

Correlative analysis on the relationship between PMI and DNA degradation of cell nucleus in human different tissues.

Xiji Shu1, Yaling Liu, Liang Ren, Fanggang He, Hongyan Zhou, Lijiang Liu, Liang Liu.   

Abstract

To determining the postmortem interval (PMI) through quantitative analysis of the DNA degradation of cell nucleus in human brain and spleen by using image analysis technique (IAT). The brain and spleen tissues from 32 cadavers with known PMI were collected, subjected to cell smear every 1 h within the first 5-36 h after death, stained by Feulgen-Van's staining, Three indices reflecting DNA in brain cells (astrocytes) and splenic lymphocytes, including integral optical density (IOD), average optical density (AOD), average gray (AG) were measured by employing the mage analysis instrument. The results showed that IOD and AOD declined and AG increased with the prolongation of dead time within 5-36 h. A correlation between the PMI and gray parameters (IOD, AOD and AG) was identified and the corresponding regression equation was obtained. The parameters (IOD, AOD and AG) were proved to be effective quantitative indicators for accurate estimation of PMI within 5-36 h after death.

Entities:  

Mesh:

Year:  2005        PMID: 16196293     DOI: 10.1007/bf02828213

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  8 in total

1.  Capillary zone electrophoresis and artificial neural networks for estimation of the post-mortem interval (PMI) using electrolytes measurements in human vitreous humour.

Authors:  G Bocaz-Beneventi; F Tagliaro; F Bortolotti; G Manetto; J Havel
Journal:  Int J Legal Med       Date:  2002-02       Impact factor: 2.686

2.  Analysis of postmortem DNA degradation by single-cell gel electrophoresis.

Authors:  Laura A Johnson; James A J Ferris
Journal:  Forensic Sci Int       Date:  2002-03-28       Impact factor: 2.395

3.  Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF). Part II. A study of the effect of body temperature at the moment of death on the postmortem brain, liver and rectal cooling in 117 forensic cases.

Authors:  Louay M al-Alousi; Robert A Anderson; Diana M Worster; David V Land
Journal:  Forensic Sci Int       Date:  2002-02-18       Impact factor: 2.395

4.  Flow cytometric evaluation of postmortem pulp DNA degradation.

Authors:  Sonja C Boy; Herman Bernitz; Willie F P Van Heerden
Journal:  Am J Forensic Med Pathol       Date:  2003-06       Impact factor: 0.921

5.  Flies eggs: a new method for the estimation of short-term post-mortem interval?

Authors:  Benoit Bourel; Benoît Callet; Valéry Hédouin; Didier Gosset
Journal:  Forensic Sci Int       Date:  2003-07-29       Impact factor: 2.395

6.  Reevaluation of optimal Feulgen reaction for automated cytology. Influence of fixatives.

Authors:  F Giroud; M P Montmasson
Journal:  Anal Quant Cytol Histol       Date:  1989-04       Impact factor: 0.302

Review 7.  Standardization of the Feulgen reaction for absorption DNA image cytometry: a review.

Authors:  E K Schulte
Journal:  Anal Cell Pathol       Date:  1991-05       Impact factor: 2.916

8.  Is flow cytometric evaluation of DNA degradation a reliable method to investigate the early postmortem period?

Authors:  N R Di Nunno; F Costantinides; P Bernasconi; C Bottin; M Melato
Journal:  Am J Forensic Med Pathol       Date:  1998-03       Impact factor: 0.921

  8 in total
  2 in total

1.  Image analysis on corneal opacity: a novel method to estimate postmortem interval in rabbits.

Authors:  Lan Zhou; Yan Liu; Liang Liu; Luo Zhuo; Man Liang; Fan Yang; Liang Ren; Shaohua Zhu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2010-04-21

2.  The Role of DNA Degradation in the Estimation of Post-Mortem Interval: A Systematic Review of the Current Literature.

Authors:  Pamela Tozzo; Salvatore Scrivano; Matteo Sanavio; Luciana Caenazzo
Journal:  Int J Mol Sci       Date:  2020-05-17       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.