Literature DB >> 16195073

Impaction bone grafting with hydroxyapatite: increased femoral component stability in experiments using Sawbones.

Takaaki Fujishiro1, Tetsuo Nishikawa, Takahiro Niikura, Satoshi Takikawa, Takayuki Nishiyama, Kiyonori Mizuno, Shinichi Yoshiya, Masahiro Kurosaka.   

Abstract

BACKGROUND: Substantial bone loss and bone defects increase the amount of allografting required in hip revision surgery. Thus, the use of a synthetic material to limit the amount of allograft tissue required for impaction grafting is desirable. We evaluated the potential of hydroxyapatite (HA) mixtures to provide initial mechanical stability to a polished tapered femoral stem.
MATERIAL AND METHODS: We determined the initial stability of a polished tapered femoral stem after reconstructing a cavitary femoral bone defect by impaction bone grafting with cement in Sawbones composite femurs. Three types of graft material were tested for their ability to improve initial rotational stability. The graft materials investigated were pure allograft, a mixture of 50% allograft and 50% hydroxyapatite (HA), and pure HA.
RESULTS: We found a statistically significant difference between the three groups as regards torsional micromotion and failure load.
INTERPRETATION: Our findings suggest that reconstruction of femoral bone defects with pure HA or a mixture of allograft and HA provides adequate initial stability for femoral revision arthroplasty using impaction grafting.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16195073     DOI: 10.1080/17453670510041556

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  8 in total

1.  Stability of fused versus nonfused THA femoral impaction grafts.

Authors:  Anneliese D Heiner; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

2.  Factors influencing the stability of stems fixed with impaction graft in vitro.

Authors:  Hirotsugu Ohashi; Masanori Matsuura; Tsuneyuki Ebara; Yusaku Okamoto; Hironori Kou
Journal:  Clin Orthop Relat Res       Date:  2009-01-29       Impact factor: 4.176

3.  Aperture fixation instead of transverse tunnels at the patella for medial patellofemoral ligament reconstruction.

Authors:  Onur Hapa; Ertuğrul Akşahin; Raif Özden; Murad Pepe; Ahmet Nedim Yanat; Yunus Doğramacı; Ergun Bozdağ; Emin Sünbüloğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-16       Impact factor: 4.342

4.  Evaluation of the effect of custom burr holes on a surgeon's sense of screw fixation in revision porous metal cups.

Authors:  Mark A Nyland; Brent A Lanting; Hristo N Nikolov; Lyndsay E Somerville; Matthew G Teeter; James L Howard
Journal:  J Orthop       Date:  2015-10-19

5.  Influence of antibiotic pellets on pore size and shear stress resistance of impacted native and thermodisinfected cancellous bone: An in vitro femoral impaction bone grafting model.

Authors:  C Fölsch; J Bok; G A Krombach; M Rickert; C A Fonseca Ulloa; G A Ahmed; M Kampschulte; A Jahnke
Journal:  J Orthop       Date:  2020-09-19

6.  Major bone defect treatment with an osteoconductive bone substitute.

Authors:  Stefania Paderni; S Terzi; L Amendola
Journal:  Chir Organi Mov       Date:  2009-06-16

7.  Effect of Hydroxyapatite porous characteristics on healing outcomes in rabbit posterolateral spinal fusion model.

Authors:  Makoto Motomiya; Manabu Ito; Masahiko Takahata; Ken Kadoya; Kazuharu Irie; Kuniyoshi Abumi; Akio Minami
Journal:  Eur Spine J       Date:  2007-09-22       Impact factor: 3.134

8.  Effect of synthetic bone replacement material of different size on shear stress resistance within impacted native and thermodisinfected cancellous bone: an in vitro femoral impaction bone grafting model.

Authors:  C Fölsch; P Sahm; C A Fonseca Ulloa; G A Krombach; M Kampschulte; M Rickert; A Pruss; A Jahnke
Journal:  Cell Tissue Bank       Date:  2021-04-24       Impact factor: 1.522

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.