Literature DB >> 16194575

Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays--LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5.

Antigoni Katsoulidou1, Maria Petrodaskalaki, Vana Sypsa, Eleni Papachristou, Cleo G Anastassopoulou, Panagiotis Gargalianos, Anastasia Karafoulidou, Marios Lazanas, Theodoros Kordossis, Anastasia Andoniadou, Angelos Hatzakis.   

Abstract

The COBAS TaqMan HIV-1 test (Roche Diagnostics) was compared with the LCx HIV RNA quantitative assay (Abbott Laboratories), the Versant HIV-1 RNA 3.0 (bDNA) assay (Bayer) and the COBAS Amplicor HIV-1 Monitor v1.5 test (Roche Diagnostics), using plasma samples of various viral load levels from HIV-1-infected individuals. In the comparison of TaqMan with LCx, TaqMan identified as positive 77.5% of the 240 samples versus 72.1% identified by LCx assay, while their overall agreement was 94.6% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.91). Similarly, in the comparison of TaqMan with bDNA 3.0, both methods identified 76.3% of the 177 samples as positive, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.95). Finally, in the comparison of TaqMan with Monitor v1.5, TaqMan identified 79.5% of the 156 samples as positive versus 80.1% identified by Monitor v1.5, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.96). In conclusion, the new COBAS TaqMan HIV-1 test showed excellent agreement with other widely used commercially available tests for the quantitation of HIV-1 viral load.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16194575     DOI: 10.1016/j.jviromet.2005.07.014

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  14 in total

1.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

2.  Highly active antiretroviral therapy potently suppresses HIV infection in humanized Rag2-/-gammac-/- mice.

Authors:  Kaori Sango; Aviva Joseph; Mahesh Patel; Kristin Osiecki; Monica Dutta; Harris Goldstein
Journal:  AIDS Res Hum Retroviruses       Date:  2010-07       Impact factor: 2.205

3.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

4.  Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test and identification of rare polymorphisms potentially affecting assay performance.

Authors:  Michael T Pyne; Katherine L Brown; David R Hillyard
Journal:  J Clin Microbiol       Date:  2010-06-23       Impact factor: 5.948

5.  Cost ramifications of increased reporting of detectable plasma HIV-1 RNA levels by the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 version 1.0 viral load test.

Authors:  James H Willig; Christa R Nevin; James L Raper; Michael S Saag; Michael J Mugavero; Amanda L Willig; Jeffrey H Burkhardt; Joseph E Schumacher; Victoria A Johnson
Journal:  J Acquir Immune Defic Syndr       Date:  2010-08       Impact factor: 3.731

6.  Single-copy quantification of HIV-1 in clinical samples.

Authors:  Ann Wiegand; Frank Maldarelli
Journal:  Methods Mol Biol       Date:  2014

7.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

8.  Evaluation of quantification of HIV-1 RNA viral load in plasma and dried blood spots by use of the semiautomated Cobas Amplicor assay and the fully automated Cobas Ampliprep/TaqMan assay, version 2.0, in Kisumu, Kenya.

Authors:  Kenneth N Ouma; Sridhar V Basavaraju; Jully A Okonji; John Williamson; Timothy K Thomas; Lisa A Mills; John N Nkengasong; Clement Zeh
Journal:  J Clin Microbiol       Date:  2013-02-06       Impact factor: 5.948

9.  Ten years of external quality assessment of human immunodeficiency virus type 1 RNA quantification.

Authors:  Brigitte Senechal; Vivienne L A James
Journal:  J Clin Microbiol       Date:  2012-09-05       Impact factor: 5.948

10.  Correction of underquantification of human immunodeficiency virus type 1 load with the second version of the Roche Cobas AmpliPrep/Cobas TaqMan assay.

Authors:  A De Bel; D Marissens; L Debaisieux; C Liesnard; S Van den Wijngaert; S Lauwers; D Piérard
Journal:  J Clin Microbiol       Date:  2010-02-17       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.