Literature DB >> 16193827

Auto-positive end-expiratory pressure: mechanisms and treatment.

Majid M Mughal1, Daniel A Culver, Omar A Minai, Alejandro C Arroliga.   

Abstract

Auto-positive end-expiratory pressure (auto-PEEP) is a common problem in patients receiving full or partial ventilatory support, as well as in those ready to be weaned from the ventilator. Physicians should be alert for it and take measures to reduce it, as it can have serious consequences.

Entities:  

Mesh:

Year:  2005        PMID: 16193827     DOI: 10.3949/ccjm.72.9.801

Source DB:  PubMed          Journal:  Cleve Clin J Med        ISSN: 0891-1150            Impact factor:   2.321


  5 in total

1.  A mathematical model for carbon dioxide elimination: an insight for tuning mechanical ventilation.

Authors:  Anake Pomprapa; David Schwaiberger; Burkhard Lachmann; Steffen Leonhardt
Journal:  Eur J Appl Physiol       Date:  2013-10-27       Impact factor: 3.078

2.  Positive end-expiratory pressure attenuates hemodynamic effects induced by an overload of inspiratory muscles in patients with COPD.

Authors:  Flavia Schaper-Magalhães; José Felippe Pinho; Carolina Andrade Bragança Capuruço; Maria Glória Rodrigues-Machado
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-10-06

3.  Comparisons of Pressure-controlled Ventilation with Volume Guarantee and Volume-controlled 1:1 Equal Ratio Ventilation on Oxygenation and Respiratory Mechanics during Robot-assisted Laparoscopic Radical Prostatectomy: a Randomized-controlled Trial.

Authors:  Min-Soo Kim; Sarah Soh; So Yeon Kim; Min Sup Song; Jin Ha Park
Journal:  Int J Med Sci       Date:  2018-10-20       Impact factor: 3.738

4.  Pressure-Controlled Ventilation with Volume Guarantee Compared to Volume-Controlled Ventilation with Equal Ratio in Obese Patients Undergoing Laparoscopic Hysterectomy.

Authors:  Mona Gad; Khaled Gaballa; Ahmed Abdallah; Mohamed Abdelkhalek; Abdelhady Zayed; Hanan Nabil
Journal:  Anesth Essays Res       Date:  2019 Apr-Jun

5.  Comments on the use of expiratory time constant for determinations of plateau pressure, respiratory system compliance, and total resistance.

Authors:  Paolo Barbini
Journal:  Crit Care       Date:  2013-03-27       Impact factor: 9.097

  5 in total