Literature DB >> 16193471

Simultaneous measurement of blood and myocardial velocity in the rat heart by phase contrast MRI using sparse q-space sampling.

Richard G Wise1, Ahmad I M Al-Shafei, T Adrian Carpenter, Laurance D Hall, Christopher L-H Huang.   

Abstract

PURPOSE: To measure cardiac blood flow patterns and ventricular wall velocities through the cardiac cycle in anesthetized Wistar Kyoto (WKY) rats.
MATERIALS AND METHODS: A gradient-echo cine pulse sequence incorporating pulsed field gradients (PFGs) provided phase contrast (PC) motion encoding. We achieved a range of velocity sensitivity that was sufficient to measure simultaneously the large flow velocities within the cardiac chambers and aortic outflow tract (up to 70 cm s(-1) during systole), and the comparatively small velocities of the cardiac wall (0-3 cm s(-1)). A scheme of sparsely sampling q-space combined with a probability-based method of velocity calculation permitted such measurements along three orthogonal axes, and yielded velocity vector maps in all four chambers of the heart and the aorta, in both longitudinal and transverse sections, for up to 12 time-points in the cardiac cycle.
RESULTS: Left ventricular systole was associated with a symmetrical laminar flow pattern along the cardiac axis, with no appearance of turbulence. In contrast, blood showed a swirling motion within the right ventricle (RV) in the region of the pulmonary outflow tract. During left ventricular diastole a plume of blood entered the left ventricle (LV) from the left atrium. The ventricular flow patterns could also be correlated with measurements of left ventricular wall motion. The greatest velocities of the ventricular walls occurred in the transverse cardiac plane and were maximal during diastolic refilling. The cardiac wall motion in the longitudinal axis demonstrated a caudal-apical movement that may also contribute to diastolic refilling.
CONCLUSION: The successful measurements of blood and myocardial velocity during normal myocardial function may be extended to quantify pathological cardiac changes in animal models of human cardiac disease. J. Magn. Reson. Imaging 2005. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16193471     DOI: 10.1002/jmri.20423

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Validation of high-resolution echocardiography and magnetic resonance imaging vs. high-fidelity catheterization in experimental pulmonary hypertension.

Authors:  Dalia Urboniene; Idith Haber; Yong-Hu Fang; Thenappan Thenappan; Stephen L Archer
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2010-06-25       Impact factor: 5.464

2.  Imaging of wall motion coupled with blood flow velocity in the heart and vessels in vivo: a feasibility study.

Authors:  Jianwen Luo; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2011-05-05       Impact factor: 2.998

3.  Characterization of three-dimensional myocardial deformation in the mouse heart: an MR tagging study.

Authors:  Jia Zhong; Wei Liu; Xin Yu
Journal:  J Magn Reson Imaging       Date:  2008-06       Impact factor: 4.813

4.  Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery.

Authors:  Shao-Chieh Chiu; Shih-Ting Hsu; Chiun-Wei Huang; Wu-Chung Shen; Shin-Lei Peng
Journal:  J Vis Exp       Date:  2018-09-05       Impact factor: 1.355

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.