Literature DB >> 16193468

k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor.

Feng Huang1, James Akao, Sathya Vijayakumar, George R Duensing, Mark Limkeman.   

Abstract

A novel technique called "k-t GRAPPA" is introduced for the acceleration of dynamic magnetic resonance imaging. Dynamic magnetic resonance images have significant signal correlations in k-space and time dimension. Hence, it is feasible to acquire only a reduced amount of data and recover the missing portion afterward. Generalized autocalibrating partially parallel acquisitions (GRAPPA), as an important parallel imaging technique, linearly interpolates the missing data in k-space. In this work, it is shown that the idea of GRAPPA can also be applied in k-t space to take advantage of the correlations and interpolate the missing data in k-t space. For this method, no training data, filters, additional parameters, or sensitivity maps are necessary, and it is applicable for either single or multiple receiver coils. The signal correlation is locally derived from the acquired data. In this work, the k-t GRAPPA technique is compared with our implementation of GRAPPA, TGRAPPA, and sliding window reconstructions, as described in Methods. The experimental results manifest that k-t GRAPPA generates high spatial resolution reconstruction without significant loss of temporal resolution when the reduction factor is as high as 4. When the reduction factor becomes higher, there might be a noticeable loss of temporal resolution since k-t GRAPPA uses temporal interpolation. Images reconstructed using k-t GRAPPA have less residue/folding artifacts than those reconstructed by sliding window, much less noise than those reconstructed by GRAPPA, and wider temporal bandwidth than those reconstructed by GRAPPA with residual k-space. k-t GRAPPA is applicable to a wide range of dynamic imaging applications and is not limited to imaging parts with quasi-periodic motion. Since only local information is used for reconstruction, k-t GRAPPA is also preferred for applications requiring real time reconstruction, such as monitoring interventional MRI. (c) 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16193468     DOI: 10.1002/mrm.20641

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  67 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  K-space reconstruction with anisotropic kernel support (KARAOKE) for ultrafast partially parallel imaging.

Authors:  Jun Miao; Wilbur C K Wong; Sreenath Narayan; David L Wilson
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 3.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

4.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

Review 5.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

6.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

7.  Accelerated dual-venc 4D flow MRI for neurovascular applications.

Authors:  Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

8.  Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI.

Authors:  Michael J Rose; Kelly Jarvis; Varun Chowdhary; Alex J Barker; Bradley D Allen; Joshua D Robinson; Michael Markl; Cynthia K Rigsby; Susanne Schnell
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

9.  Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

Authors:  Feiyu Chen; Tao Zhang; Joseph Y Cheng; Xinwei Shi; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2016-12-09       Impact factor: 4.668

10.  Robust 4D flow denoising using divergence-free wavelet transform.

Authors:  Frank Ong; Martin Uecker; Umar Tariq; Albert Hsiao; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.