Literature DB >> 16185703

Determination of glyphosate and phosphate in water by ion chromatography--inductively coupled plasma mass spectrometry detection.

Zhong-Xian Guo1, Qiantao Cai, Zhaoguang Yang.   

Abstract

Quantitative determination of trace glyphosate and phosphate in waters was achieved by coupling ion chromatography (IC) separation with inductively coupled plasma mass spectrometry (ICP-MS) detection. The separation of glyphosate and phosphate on a polymer anion-exchange column (Dionex IonPac AS16, 4.0 mm x 250 mm) was obtained by eluting them with 20 mM citric acid at 0.50 mL min(-1), and the analytes were detected directly and selectively by ICP-MS at m/z = 31. Parameters affecting their chromatographic behaviors and ICP-MS characteristics were systematically examined. Based on a 500-microL sample injection volume, the detection limits were 0.7 microgL(-1) for both glyphosate and phosphate, and the calibrations were linear up to 400 microgL(-1). Polyphosphates, aminomethylphosphonic acid (the major metabolite of glyphosate), non-polar and other polar phosphorus-containing pesticides showed different chromatographic behaviors from the analytes of interest and therefore did not interference. The determination was also interference free from the matrix anions (nitrate, nitrite, sulphate, chloride, etc.) and metallic ions. The analysis of certified reference material, drinking water, reservoir water and Newater yielded satisfactory results with spiked recoveries of 97.1-107.0% and relative standard deviations of < or = 7.4% (n = 3). Compared to other reported methods for glyphosate and phosphate, the developed IC-ICP-MS method is sensitive and simple, and does not require any chemical derivatization, sample preconcentration and mobile phase conductivity suppression.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16185703     DOI: 10.1016/j.chroma.2005.09.034

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Ratiometric fluorescence sensor for sensitive detection of inorganic phosphate in environmental samples.

Authors:  Zhao Zhang; Huihui Tao; Qiao Cao; Lingfei Li; Shihao Xu; Yucheng Li; Yingying Liu
Journal:  Anal Bioanal Chem       Date:  2022-02-23       Impact factor: 4.478

2.  SERS Determination of Trace Phosphate in Aquaculture Water Based on a Rhodamine 6G Molecular Probe Association Reaction.

Authors:  Ye Jiang; Xiaochan Wang; Guo Zhao; Yinyan Shi; Nguyen Thi Dieu Thuy; Haolin Yang
Journal:  Biosensors (Basel)       Date:  2022-05-10

3.  Highly Selective Polypyrrole MIP-Based Gravimetric and Electrochemical Sensors for Picomolar Detection of Glyphosate.

Authors:  Zouhour Mazouz; Seyfeddine Rahali; Najla Fourati; Chouki Zerrouki; Nadia Aloui; Mahamadou Seydou; Nourdin Yaakoubi; Mohamed M Chehimi; Ali Othmane; Rafik Kalfat
Journal:  Sensors (Basel)       Date:  2017-11-09       Impact factor: 3.576

  3 in total