Literature DB >> 16181209

A noninvasive strategy for screening prospective blood donors for anemia.

Ramin Lotfi1, Dorothee Wernet, Uwe Starke, Hinnak Northoff, Uwe Cassens.   

Abstract

BACKGROUND: The reliability of capillary hemoglobin (Hb) as an indicator for eligibility to donate blood is discussed controversially. Therefore, a noninvasive alternative with acceptable predictive values was established and evaluated. STUDY DESIGN AND METHODS: Donor candidates were selected according to their Hb level. The first donation was performed 6 weeks after this selection step. A venous blood sample was collected from all donors at the end of their donation and a postdonation Hb determination was performed. Donors with acceptable postdonation Hb values were permitted to donate next time without any predonation Hb measurement. Donors with low postdonation Hb values were permitted to donate only after a venous Hb measurement had shown an acceptable value. Sensitivity and specificity were determined by comparing the gold standard (i.e., venous Hb measurement) with the presented method of Hb estimation for 19,534 donors.
RESULTS: Taking the postdonation Hb as an indicator for eligibility saved 97 percent of donors from being tested unnecessarily by capillary Hb measurement. This procedure resulted in a specificity of 92.6 percent and a sensitivity of 37.9 percent for Hb cutoff levels of 135 and 125 g per L for men and women, respectively. The sensitivity increased rapidly to 100 percent for Hb levels below 105 g per L. The average deviation from true Hb level was 6 g per L.
CONCLUSION: The presented noninvasive method distinctly saves time and expenditure without endangering blood donors.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16181209     DOI: 10.1111/j.1537-2995.2005.00574.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  7 in total

1.  Capillary versus venous haemoglobin determination in the assessment of healthy blood donors.

Authors:  A J Patel; R Wesley; S F Leitman; B J Bryant
Journal:  Vox Sang       Date:  2013-01-07       Impact factor: 2.144

2.  Hepcidin/Ferritin Quotient Helps to Predict Spontaneous Recovery from Iron Loss following Blood Donation.

Authors:  Ramin Lotfi; Christine Kroll; Dietmar Plonné; Bernd Jahrsdörfer; Hubert Schrezenmeier
Journal:  Transfus Med Hemother       Date:  2015-11-03       Impact factor: 3.747

Review 3.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

4.  Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening.

Authors:  Moon Jung Kim; Quehn Park; Myung Hee Kim; Jeong Won Shin; Hyun Ok Kim
Journal:  Ann Lab Med       Date:  2013-06-24       Impact factor: 3.464

5.  Investigating the importance of haemoglobin measurement for selection of blood donors in libya.

Authors:  Ai Abud; Am Bashein; Aa Msalati
Journal:  Libyan J Med       Date:  2009-12-01       Impact factor: 1.657

Review 6.  Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions.

Authors:  Rajendra Chaudhary; Anju Dubey; Atul Sonker
Journal:  J Blood Med       Date:  2017-07-03

7.  Comparison of four methods to measure haemoglobin concentrations in whole blood donors (COMPARE): A diagnostic accuracy study.

Authors:  Steven Bell; Michael Sweeting; Anna Ramond; Ryan Chung; Stephen Kaptoge; Matthew Walker; Thomas Bolton; Jennifer Sambrook; Carmel Moore; Amy McMahon; Sarah Fahle; Donna Cullen; Susan Mehenny; Angela M Wood; Jane Armitage; Willem H Ouwehand; Gail Miflin; David J Roberts; John Danesh; Emanuele Di Angelantonio
Journal:  Transfus Med       Date:  2020-12-20       Impact factor: 2.019

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.