Literature DB >> 16180402

Transarterial coil embolization for canine patent ductus arteriosus occlusion.

S G Gordon1, M W Miller.   

Abstract

Left to right shunting patent ductus arteriosus (PDA) is the most common canine congenital heart defect. If not occluded PDA is associated with high morbidity and mortality. Historically, surgical ligation has been the standard method of correction. Although highly successful, surgical ligation is associated with some operative morbidity and mortality. More recently, minimally invasive transcatheter techniques have been employed for PDA occlusion. Transarterial PDA coil embolization is a safe, cost effective, less invasive alternative offered by many specialty centers for PDA occlusion. This procedure involves catheterization of the femoral artery under general anesthesia. An angiogram is then performed to delineate PDA morphology and facilitate coil selection. Coils are commercially available and composed of surgical stainless steel with prothrombotic poly-Dacron fibers. Coils are advanced through a catheter into the PDA under fluoroscopic guidance until satisfactory angiographic occlusion is documented. Patients are then recovered and released the following day. This procedure requires substantial technical expertise and specialized equipment.

Entities:  

Mesh:

Year:  2005        PMID: 16180402     DOI: 10.1053/j.ctsap.2005.05.008

Source DB:  PubMed          Journal:  Clin Tech Small Anim Pract        ISSN: 1096-2867


  4 in total

1.  An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

Authors:  Mark A Wierzbicki; Sarah B Raines; Sonya G Gordon; John C Criscione; Ashley B Saunders; Scott Birch; Bradley Due; Brandis Keller; Landon D Nash; Matthew W Miller; Duncan J Maitland
Journal:  J Mech Behav Biomed Mater       Date:  2017-07-25

2.  Goiter with vascular anomalies in a litter of Polish Lowland sheepdogs.

Authors:  Leslie Anne Kuczynski; Paul Schwartz; Gordon Peddle; Steven Huang; Wilfried Mai; Urs Giger
Journal:  J Am Anim Hosp Assoc       Date:  2012-05-18       Impact factor: 1.023

3.  Retrieval of an embolization coil accidentally dislodged in the descending aorta of a dog with a patent ductus arteriosus.

Authors:  Seung Gon Lee; Changbaig Hyun
Journal:  J Vet Sci       Date:  2007-06       Impact factor: 1.672

4.  Mechanical and in vitro evaluation of an experimental canine patent ductus arteriosus occlusion device.

Authors:  Mark A Wierzbicki; Jesse Bryant; Matthew W Miller; Brandis Keller; Duncan J Maitland
Journal:  J Mech Behav Biomed Mater       Date:  2015-12-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.