Literature DB >> 16178654

Near-UV/blue light-induced fluorescence in the human lens: potential interference with visual function.

Joseph A Zuclich1, Fred H Previc, Brenda J Novar, Peter R Edsall.   

Abstract

Irradiation of the ocular lens of numerous species by near-UV or short-visible wavelengths induces a blue-green fluorescence, which can be a source of intraocular veiling glare. Wavelengths longer than the approximately 365-nm lens absorption peak induce progressively weaker but also progressively more red-shifted fluorescence emission. The more red-shifted emission has a higher luminous efficiency and, in fact, earlier studies in this laboratory have demonstrated that the lens fluorescence in the nonhuman primate yields an approximately constant luminous efficiency when excited by equal radiant exposures over the wavelength range from 350 to 430 nm. Now, with the recent development and projected widespread use of "blue" diode lasers, a further study extending the measurements of the induced fluorescence efficiency and of the consequent veiling glare to the human lens seemed timely. The current study quantifies the fluorescence intensity induced in the human lens, both in terms of radiance and luminance, as a function of exciting light intensity, excitation wavelength, and subject age. The spatial distribution of the emitted fluorescence is also examined. These data are shown to imply that exposure to near-UV/blue wavelength sources at "safe" exposure levels (according to existing laser safety standards) can induce a veiling glare intense enough to degrade visual performance, and that the fluorescence intensity and consequent glare disruption show little dependence on subject age.

Entities:  

Mesh:

Year:  2005        PMID: 16178654     DOI: 10.1117/1.1990163

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  5 in total

Review 1.  What is light? The visible spectrum and beyond.

Authors:  D H Sliney
Journal:  Eye (Lond)       Date:  2016-01-15       Impact factor: 3.775

Review 2.  Which lamp will be optimum to eye? Incandescent, fluorescent or LED etc.

Authors:  Liang Chen; Xiao-Wei Zhang
Journal:  Int J Ophthalmol       Date:  2014-02-18       Impact factor: 1.779

3.  Impact of cataract on the spectral measurement of fundus autofluorescence.

Authors:  Rowena Simon; Jakob Lauritz Brauer; Daniel Meller; Martin Hammer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-01-12       Impact factor: 3.535

4.  Individual variation in the transmission of UVB radiation in the young adult eye.

Authors:  Billy R Hammond; Lisa Renzi-Hammond
Journal:  PLoS One       Date:  2018-07-12       Impact factor: 3.240

5.  Effects of color lenses on visual evoked magnetic fields following bright light.

Authors:  Masaya Suzuki; Naoya Kumagai; Koji Inui; Ryusuke Kakigi
Journal:  PLoS One       Date:  2018-08-02       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.