Literature DB >> 16177436

Contrast-enhanced MR angiography of subclavian steal syndrome: value of the 2D time-of-flight "localizer" sign.

Niall Sheehy1, Sorcha MacNally, Clare S Smith, Gerard Boyle, Prakash Madhavan, James F M Meaney.   

Abstract

OBJECTIVE: Our objective was to determine if direction of flow within the vertebral artery could be reliably determined by evaluation of flow-sensitive, low-resolution 2D time-of-flight (TOF) localizer images taken before 3D contrast-enhanced MR angiography (3D CEMRA) sequences in patients with unsuspected subclavian steal syndrome.
CONCLUSION: Vertebral artery patency on 3D CEMRA in cases in which the vessel is absent on the TOF localizer in association with ipsilateral subclavian artery stenosis indicates reversal of flow in the vertebral artery and confirms the subclavian steal phenomenon. The combination of anatomic imaging with 3D CEMRA with functional information provided by the low-resolution TOF localizer confirms the diagnosis of subclavian steal without additional imaging.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16177436     DOI: 10.2214/AJR.04.1130

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  20-year-old injury: an unusual cause of stroke.

Authors:  V W L Lim; C A Flynn; M O'Connor; D Lyons
Journal:  BMJ Case Rep       Date:  2013-04-19

2.  Ruptured vertebrobasilar junction aneurysm unmasking subclavian steal syndrome.

Authors:  Vivek Murumkar; Shumyla Jabeen; Sameer Peer; Aravinda Hanumanthapura Ramalingaiah; Jitender Saini
Journal:  Surg Neurol Int       Date:  2020-12-04
  2 in total