A procedure is described for the quantitation of zearalenone from corn by gas-liquid chromatography. An internal standard, zearalanone, is first mixed with the finely ground corn, followed by extraction with ethyl acetate, purification by thin-layer chromatography and formation of trimethyl silyl ether (TMS) and methyl oxime (MOX) derivatives. Positive identification of zearalenone is based upon the retention times of the TMS and MOX-TMS derivatives being identical with those of the standards, comparison of chromatograms from both derivatives and characteristic twin peaks of zearalenone MOX-TMS. The detection limit of 100 parts per 10(9) zearalenone in corn could only be improved by modification of the described procedure.Entities:
Mesh:
Substances:
Year: 1979 PMID: 161764 DOI: 10.1016/s0021-9673(00)84248-x