Tandem mass spectrometry method for the quantification of serum busulfan.

M D Kellogg1, T Law, M Sakamoto, N Rifai.   

Abstract

Busulfan, an alkylating agent, is most commonly used as a component of bone marrow transplantation preoperative regimens. Significant interpatient and intrapatient variations in pharmacokinetics require individualizing the dosage based on area under the time-versus-concentration curve. Timely result reporting is critical to dose adjustment to reduce morbidity and mortality associated with the regimen. The authors developed a rapid, accurate, and sensitive method for the quantification of serum busulfan using direct inject tandem mass spectrometry. Plasma samples (50 microL) are extracted in 1 mL of methanol containing 1,6-bis-(methanesulfonyloxy)hexane as an internal standard. The supernatant is dried under nitrogen (40 degrees C, 30 minutes) and then dissolved in 200 microL methanol and transferred into a clean glass vial suitable for LC/MS/MS analysis. The sample is delivered using an HPLC pump that delivers 0.2 mL of methanol per minute, and 20 microL of sample is injected into a turbo ion spray-equipped tandem mass spectrometer. Total analysis time is 5 minutes. The Q1/Q3 transition for busulfan (BU) is monitored at 269/55 and 297.1/55.1 for the internal standard. The assay is linear to 10 micromol/L and sensitive to at least 0.5 micromol/L. The interassay reproducibility at 1, 2.2, and 4.4 micromol/L were 4.2%, 5.6%, and 6.3%, respectively. Within-run precision using 3 different control samples was 3.9%, 3.9%, and 6.9%. Mean recovery of 4 different BU concentrations spiked into 10 different BU free plasma samples was 98%. Correlation with an established HPLC-UV method revealed a slope of 0.98, an intercept of 0.1, and r = 0.95 (n = 48). No significant interfering substances or ion suppression was identified. This method is a significant improvement over the existing HPLC-UV method for BU determination. The method is highly accurate, reproducible, and requires less specimen, sample preparation, and analysis time.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16175136     DOI: 10.1097/01.ftd.0000173372.04945.7b

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  7 in total

1.  Effect of weight and maturation on busulfan clearance in infants and small children undergoing hematopoietic cell transplantation.

Authors:  Radojka M Savic; Morton J Cowan; Christopher C Dvorak; Sung-Yun Pai; Luis Pereira; Imke H Bartelink; Jaap J Boelens; Robbert G M Bredius; Rob F Wynn; Geoff D E Cuvelier; Peter J Shaw; Mary A Slatter; Janel Long-Boyle
Journal:  Biol Blood Marrow Transplant       Date:  2013-09-09       Impact factor: 5.742

2.  Limited sampling strategy for predicting busulfan exposure in hematopoietic stem cell transplantation recipients.

Authors:  Jing-Jing Huang; Bing Chen; Jiong Hu; Wan-Hua Yang
Journal:  Int J Clin Pharm       Date:  2017-05-29

3.  Quantification of busulfan in saliva and plasma in haematopoietic stem cell transplantation in children : validation of liquid chromatography tandem mass spectrometry method.

Authors:  Manfred Rauh; Daniel Stachel; Michaela Kuhlen; Michael Gröschl; Wolfgang Holter; Wolfgang Rascher
Journal:  Clin Pharmacokinet       Date:  2006       Impact factor: 6.447

4.  An LC-MS Assay with Isocratic Separation and On-line Solid Phase Extraction to Improve the Routine Therapeutic Drug Monitoring of Busulfan in Plasma.

Authors:  Cristiano Ialongo; Alessia Francesca Mozzi; Sergio Bernardini
Journal:  J Med Biochem       Date:  2017-04-22       Impact factor: 3.402

5.  A rapid & sensitive liquid chromatography- tandem mass spectrometry method for the quantitation of busulfan levels in plasma & application for routine therapeutic monitoring in haematopoietic stem cell transplantation.

Authors:  Salamun Desire; Ezhil Pavai Mohanan; Biju George; Vikram Mathews; Mammen Chandy; Alok Srivastava; Poonkuzhali Balasubramanian
Journal:  Indian J Med Res       Date:  2013-04       Impact factor: 2.375

6.  Quantification of human plasma-busulfan concentration by liquid chromatography-tandem mass spectrometry.

Authors:  Soo Young Moon; Min Kyoo Lim; Susie Hong; Yongbum Jeon; Minje Han; Sang Hoon Song; Kyoung Soo Lim; Kyung-Sang Yu; In-Jin Jang; Ji Won Lee; Hyoung Jin Kang; Junghan Song
Journal:  Ann Lab Med       Date:  2013-12-06       Impact factor: 3.464

7.  Evaluation of a Nanoparticle-Based Busulfan Immunoassay for Rapid Analysis on Routine Clinical Analyzers.

Authors:  Mary Rose Hilaire; Regina V Gill; Jodi B Courtney; Irina Baburina; JoAnn Gardiner; Michael C Milone; Leslie M Shaw; Qing H Meng; Salvatore J Salamone
Journal:  Ther Drug Monit       Date:  2021-12-01       Impact factor: 3.681

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.