| Literature DB >> 16172708 |
Roberto Sergio Martins1, Mario Gilberto Siqueira, Ciro Ferreira da Silva, Benedito Ortiz de Godoy, José Píndaro Pereira Plese.
Abstract
We evaluated the repair of sectioned rat sciatic nerve by the comparison of electrophysiologic parameters. The repair was effected with suture (group A), fibrin glue (group B) or a combination of both techniques (group C). The amplitude, latency and conduction velocity of the motor and nerve action potentials were assessed before the nerve section and at reoperation after 24 weeks. There was no difference between the groups when the nerve action potential was evaluated. Rats of group B presented better results than those of group A (p<0.05) when latency and the nerve conduction velocity assessed at the reoperation, and the ratio between the conduction velocity at the reoperation and before the nerve section in the motor action potential evaluation were measured. Animals of group C presented better results than those of group A when the ratio between the conduction velocity of motor action potential at the reoperation and before the nerve division was considered (p<0.05). No difference between groups B and C was found. We conclude that repair using fibrin glue presented better results than suture following transection of sciatic nerve when the motor action potential was evaluated in the rat experimental model.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16172708 DOI: 10.1590/s0004-282x2005000400009
Source DB: PubMed Journal: Arq Neuropsiquiatr ISSN: 0004-282X Impact factor: 1.420