Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL.

Gossett A Campbell1, Raj Mutharasan.   

Abstract

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 2.48 mm2 were fabricated. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10(6) spores/mL). The resonant frequency decreased at a rate proportional to the spore concentration and reached a steady state frequency change of 5+/-5 Hz (n=3), 92+/-7 Hz (n=3), 500+/-10 Hz (n=3), 1030+/-10 Hz (n=2), and 2696+/-6 Hz (n=2) corresponding to 0, 3x10(2), 3x10(3), 3x10(4), and 3x10(6) spores/mL, respectively. The reduction in resonant frequency is proportional to the change in cantilever mass, and thus the observed changes are due to the attachment of spores on the sensor surface. Selectivity of the antibody-functionalized sensor was determined with samples of BA (3x10(6)/mL) mixed with Bacillus thuringiensis (BT; 1.5x10(9)/mL) in various volume ratios that yielded BA:BT ratios of 1:0, 1:125, 1:250, 1:500 and 0:1. The corresponding resonance frequency decreases were, respectively, 2345, 1980, 1310, 704 and 10 Hz. Sample containing 100% BT spores (1.5x10(9)/mL and no BA) gave a steady state frequency decrease of 10 Hz, which is within noise level of the sensor, indicating excellent selectivity. The observed binding rate constant for the pure BA and BT-containing samples ranged from 0.105 to 0.043 min-1 in the spore concentration range 300 to 3x10(6)/mL. These results show that detection of B. anthracis spore at a very low concentration (300 spores/mL) and with high selectivity in presence of another Bacillus spore (BT) can be accomplished using piezoelectric-excited millimeter-sized cantilever sensors.

Entities:  

Mesh:

Year:  2005        PMID: 16169715     DOI: 10.1016/j.bios.2005.08.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Implications of limits of detection of various methods for Bacillus anthracis in computing risks to human health.

Authors:  Amanda B Herzog; S Devin McLennan; Alok K Pandey; Charles P Gerba; Charles N Haas; Joan B Rose; Syed A Hashsham
Journal:  Appl Environ Microbiol       Date:  2009-07-31       Impact factor: 4.792

Review 2.  Measurement of Mechanical Properties of Cantilever Shaped Materials.

Authors:  Eric Finot; Ali Passian; Thomas Thundat
Journal:  Sensors (Basel)       Date:  2008-05-26       Impact factor: 3.576

Review 3.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

4.  Ultrasensitive, Label Free, Chemiresistive Nanobiosensor Using Multiwalled Carbon Nanotubes Embedded Electrospun SU-8 Nanofibers.

Authors:  Matta Durga Prakash; Siva Rama Krishna Vanjari; Chandra Shekhar Sharma; Shiv Govind Singh
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.