Literature DB >> 16169266

Correction of concomitant gradient artifacts in experimental microtesla MRI.

Whittier R Myers1, Michael Mössle, John Clarke.   

Abstract

Magnetic resonance imaging (MRI) suffers from artifacts caused by concomitant gradients when the product of the magnetic field gradient and the dimension of the sample becomes comparable to the static magnetic field. To investigate and correct for these artifacts at very low magnetic fields, we have acquired MR images of a 165-mm phantom in a 66-microT field using gradients up to 350 microT/m. We prepolarize the protons in a field of about 100 mT, apply a spin-echo pulse sequence, and detect the precessing spins using a superconducting gradiometer coupled to a superconducting quantum interference device (SQUID). Distortion and blurring are readily apparent at the edges of the images; by comparing the experimental images to computer simulations, we show that concomitant gradients cause these artifacts. We develop a non-perturbative, post-acquisition phase correction algorithm that eliminates the effects of concomitant gradients in both the simulated and the experimental images. This algorithm assumes that the switching time of the phase-encoding gradient is long compared to the spin precession period. In a second technique, we demonstrate that raising the precession field during phase encoding can also eliminate blurring caused by concomitant phase-encoding gradients; this technique enables one to correct concomitant gradient artifacts even when the detector has a restricted bandwidth that sets an upper limit on the precession frequency. In particular, the combination of phase correction and precession field cycling should allow one to add MRI capabilities to existing 300-channel SQUID systems used to detect neuronal currents in the brain because frequency encoding could be performed within the 1-2 kHz bandwidth of the readout system.

Mesh:

Year:  2005        PMID: 16169266     DOI: 10.1016/j.jmr.2005.08.003

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Nuclear spin noise imaging.

Authors:  Norbert Müller; Alexej Jerschow
Journal:  Proc Natl Acad Sci U S A       Date:  2006-04-24       Impact factor: 11.205

2.  Parallel MRI at microtesla fields.

Authors:  Vadim S Zotev; Petr L Volegov; Andrei N Matlashov; Michelle A Espy; John C Mosher; Robert H Kraus
Journal:  J Magn Reson       Date:  2008-03-06       Impact factor: 2.229

3.  Noise amplification in parallel whole-head ultra-low-field magnetic resonance imaging using 306 detectors.

Authors:  Fa-Hsuan Lin; Panu T Vesanen; Jaakko O Nieminen; Yi-Cheng Hsu; Koos C J Zevenhoven; Juhani Dabek; Lauri T Parkkonen; Andrey Zhdanov; Risto J Ilmoniemi
Journal:  Magn Reson Med       Date:  2012-09-28       Impact factor: 4.668

4.  Multidimensional x-space magnetic particle imaging.

Authors:  Patrick W Goodwill; Steven M Conolly
Journal:  IEEE Trans Med Imaging       Date:  2011-03-10       Impact factor: 10.048

5.  Low-Cost High-Performance MRI.

Authors:  Mathieu Sarracanie; Cristen D LaPierre; Najat Salameh; David E J Waddington; Thomas Witzel; Matthew S Rosen
Journal:  Sci Rep       Date:  2015-10-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.