Literature DB >> 16169048

Evaluation of the emission characteristics of PCDD/Fs from electric arc furnaces.

Moo Been Chang1, Hung Chi Huang, Shian Sheng Tsai, Kai Hsien Chi, Guo Ping Chang-Chien.   

Abstract

Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/Nm(3) while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/Nm(3). The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/Nm(3) and the TEQ concentration was 0.14 ng I-TEQ/Nm(3). 1,2,3,4,6,7,8-H(p)CDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60-70%) at both EAFs investigated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16169048     DOI: 10.1016/j.chemosphere.2005.07.054

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  2 in total

1.  Residue concentrations and profiles of PCDD/Fs in ash samples from multiple thermal industrial processes in Vietnam: Formation, emission levels, and risk assessment.

Authors:  Mai Thi Ngoc Pham; Anh Quoc Hoang; Xuan Truong Nghiem; Binh Minh Tu; Thi Nhung Dao; Duc Nam Vu
Journal:  Environ Sci Pollut Res Int       Date:  2019-04-27       Impact factor: 4.223

2.  Concentration of organic micropollutants in the atmosphere of Trieste, Italy.

Authors:  S Mosca; G N Torelli; G Tramontana; E Guerriero; M Rotatori; M Bianchini
Journal:  Environ Sci Pollut Res Int       Date:  2012-07-03       Impact factor: 4.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.