Literature DB >> 16164474

Midwives' visual interpretation of intrapartum cardiotocographs: intra- and inter-observer agreement.

Declan Devane1, Joan Lalor.   

Abstract

AIM: This paper reports an examination of intra- and inter-observer agreement in midwives' visual interpretation of intrapartum cardiotocographs (CTGs).
BACKGROUND: The issue of intra- and inter-observer agreement in the interpretation of CTG interpretation has serious implications for the validity of electronic fetal heart rate monitoring and subsequent decisions on intrapartum management. However, no studies were found that assessed intra- and inter-observer agreement in midwives' interpretations of CTG tracings.
METHODS: Twenty-eight midwives independently interpreted three intrapartum CTG tracings on two separate occasions using a self-administered Cardiotocograph Interpretation Skills Test. Inter-rater agreement in interpretation was assessed by cross-tabulating the two sets of raw data obtained at time 1 and time 2 and computing Cohen's Kappa (kappa). Intra-rater agreement was assessed by computing kappa for each rater with the two sets of raw data (time 1 and time 2) obtained from each individual. The data were collected in 2000.
RESULTS: Overall intra-rater agreement ranged from 'fair to good' (kappa = 0.48) to 'excellent' (kappa = 0.92). Raters' classifications altered in 18% (n = 5) of cases for the normal tracing, in 29% (n = 8) for the suspicious tracing and in 11% (n = 3) for the pathological tracing. Inter-rater agreement was fair to good, with kappa statistics ranging from 0.65 to 0.74, respectively. Agreement was highest in the classification of decelerations (kappa = 0.79) and lowest in the assessment of baseline variability (kappa = 0.50). Overall inter-rater agreement was highest in the suspicious tracing (kappa = 0.77, excellent) and lowest in the normal tracing (kappa = 0.54, fair to good).
CONCLUSION: Inter- and intra-observer variability are intrinsic characteristics of the interpretation of intrapartum CTGs. Levels of agreement revealed degrees of variation that expose room for improvement. Efforts are needed to reduce inter- and intra-observer variation in interpretation of intrapartum CTG tracings. In addition, research should focus on the development and evaluation of non-invasive, low observer variability methods of intrapartum assessment of fetal well-being. The subjectivity of CTG interpretation and inconsistencies in interpretation should also be considered in intrapartum management, clinical audit and in medico-legal settings.

Entities:  

Mesh:

Year:  2005        PMID: 16164474     DOI: 10.1111/j.1365-2648.2005.03575.x

Source DB:  PubMed          Journal:  J Adv Nurs        ISSN: 0309-2402            Impact factor:   3.187


  10 in total

Review 1.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

Authors:  Zarko Alfirevic; Declan Devane; Gillian Ml Gyte; Anna Cuthbert
Journal:  Cochrane Database Syst Rev       Date:  2017-02-03

Review 2.  Fetal pulse oximetry for fetal assessment in labour.

Authors:  Christine E East; Lisa Begg; Paul B Colditz; Rosalind Lau
Journal:  Cochrane Database Syst Rev       Date:  2014-10-07

Review 3.  Professionals' views of fetal monitoring during labour: a systematic review and thematic analysis.

Authors:  Valerie Smith; Cecily M Begley; Mike Clarke; Declan Devane
Journal:  BMC Pregnancy Childbirth       Date:  2012-12-27       Impact factor: 3.007

4.  Assessment of coupling between trans-abdominally acquired fetal ECG and uterine activity by bivariate phase-rectified signal averaging analysis.

Authors:  Daniela Casati; Tamara Stampalija; Konstantinos Rizas; Enrico Ferrazzi; Cristina Mastroianni; Eleonora Rosti; Mariachiara Quadrifoglio; Axel Bauer
Journal:  PLoS One       Date:  2014-04-23       Impact factor: 3.240

5.  Fetal heart rate monitoring of short term variation (STV): a methodological observational study.

Authors:  Stina Wretler; Malin Holzmann; Sophie Graner; Pelle Lindqvist; Susanne Falck; Lennart Nordström
Journal:  BMC Pregnancy Childbirth       Date:  2016-03-16       Impact factor: 3.007

6.  Reducing caesarean rates in a public maternity hospital by implementing a plan of action: a quality improvement report.

Authors:  Romulo Negrini; Raquel Domingues da Silva Ferreira; Renata Silva Albino; Carol Amaral Tavares Daltro
Journal:  BMJ Open Qual       Date:  2020-05

7.  IMproving the practice of intrapartum electronic fetal heart rate MOnitoring with cardiotocography for safer childbirth (the IMMO programme): protocol for a qualitative study.

Authors:  Guillaume Lamé; Elisa Liberati; Jenni Burt; Tim Draycott; Cathy Winter; James Ward; Mary Dixon-Woods
Journal:  BMJ Open       Date:  2019-06-28       Impact factor: 2.692

8.  Intrapartum cardiotocography trace pattern pre-processing, features extraction and fetal health condition diagnoses based on RCOG guideline.

Authors:  Shahad Al-Yousif; Ihab A Najm; Hossam Subhi Talab; Nourah Hasan Al Qahtani; M Alfiras; Osama Ym Al-Rawi; Wisam Subhi Al-Dayyeni; Ali Amer Ahmed Alrawi; Mohannad Jabbar Mnati; Mu'taman Jarrar; Fahad Ghabban; Nael A Al-Shareefi; Mustafa Musa Jaber; Abbadullah H Saleh; Nooritawati Md Tahir; Huda T Najim; Mayada Taher
Journal:  PeerJ Comput Sci       Date:  2022-08-18

Review 9.  Antenatal cardiotocography for fetal assessment.

Authors:  Rosalie M Grivell; Zarko Alfirevic; Gillian M L Gyte; Declan Devane
Journal:  Cochrane Database Syst Rev       Date:  2015-09-12

10.  Protocol for a randomised controlled trial of fetal scalp blood lactate measurement to reduce caesarean sections during labour: the Flamingo trial [ACTRN12611000172909].

Authors:  Christine E East; Stefan C Kane; Mary-Ann Davey; C Omar Kamlin; Shaun P Brennecke
Journal:  BMC Pregnancy Childbirth       Date:  2015-11-03       Impact factor: 3.007

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.