Human ex vivo bone tissue strains around natural teeth vs. immediate oral implants.

Murat Cavit Cehreli1, Murat Akkocaoglu, Ayhan Comert, Ibrahim Tekdemir, Kivanc Akca.   

Abstract

PURPOSE: To compare ex vivo bone tissue strains around natural teeth with immediate implants supporting unsplinted and splinted fixed prostheses.
MATERIAL AND METHODS: Six linear strain gauges were bonded on the labial marginal bone of bilateral maxillary anterior teeth in two fresh-frozen human cadavers. The natural teeth were loaded in centric occlusion via an occlusal splint with integrated miniature load cells. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to data acquisition system. Upon extraction of the anterior teeth, Ø 4.1 mm and Ø 4.8 mm ITI dental implants were placed into sockets of incisors and canines, respectively. Installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFA) were also undertaken. Strain measurements were performed for (1) single-tooth implant restorations, (2) unilateral splinted anterior implants, and (3) bilateral splinted anterior implants. Finally, an autopolymerizing acrylic resin was injected into the implant sockets for simulation of osseointegration and strain measurements were performed.
RESULTS: Microstrains of all groups were statistically comparable (P>0.05), although lower strains were elicited for implants in sockets of incisors in comparison with natural teeth. Microstrains around canine implants were comparable or higher than those induced around natural canines. For all groups, microstrains around canines were higher than those around lateral (P<0.05) and central incisors (P<0.01), which had similar strain levels (P>0.05). The RFA values of implants were comparable. The ITVs of implants in sockets of lateral incisors and canines were similar and were higher than those of implants in central incisor regions.
CONCLUSION: The labial marginal bone having no contact with immediate implants may experience strain gradients within physiologic levels due to deformation of bone under load. Although one prosthetic design does not seem to have clear advantages over another, splinting of implants may be considered as a safety measure for immediately loaded immediate implants, if possible.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16164459     DOI: 10.1111/j.1600-0501.2005.01140.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

3.  Long-term follow-up of dental single implants under immediate orthodontic load.

Authors:  Lisiane Meira Palagi; Carlos Eduardo Sabrosa; Eveline C B Gava; Tiziano Baccetti; Jose Augusto M Miguel
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

4.  Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis.

Authors:  Luis Gustavo Oliveira de Vasconcellos; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Lea Nogueira Braulino de Melo Nishioka
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

5.  Micromotion analysis of immediately loaded implants with Titanium and Cobalt-Chrome superstructures. 3D finite element analysis.

Authors:  Julio Tobar-Reyes; Luis Andueza-Castro; Antonio Jiménez-Silva; Roger Bustamante-Plaza; Juan Carvajal-Herrera
Journal:  Clin Exp Dent Res       Date:  2021-05-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.