Literature DB >> 16159828

How to guide stent-graft implantation in type B aortic dissection? Comparison of angiography, transesophageal echocardiography, and intravascular ultrasound.

Dietmar H Koschyk1, Christoph A Nienaber, Malgorzata Knap, Thomas Hofmann, Yskert V Kodolitsch, Valeria Skriabina, Mohammed Ismail, Olaf Franzen, Tim C Rehders, Christoph Dieckmann, Gunnar Lund, Hermann Reichenspurner, Thomas Meinertz.   

Abstract

BACKGROUND: Despite growing interest in stent-graft implantation for type-B aortic dissection, there are no established recommendations to prepare and perform an implantation procedure. METHODS AND
RESULTS: We directly compared angiography (ANGIO), transesophageal echocardiography (TEE), and intravascular ultrasound (IVUS) intraprocedually before and after placement of 48 stent grafts in 42 consecutive patients (12 women, 61+/-11 years of age) with acute and chronic type-B aortic dissection for both usefulness and capability to guide aortic stent-graft implantation. Both IVUS and TEE are superior to ANGIO to identify multiple entries (52 and 43 versus 34; P<0.005 each), to diagnose false-lumen slow flow after stent-graft implantation (32 and 31 versus 24; P<0.005 each) and to detect incomplete stent apposition (18 and 16 versus 8; P<0.005 each). In comparison with ANGIO, guide wire position over the entire length of the aorta was documented more frequently by TEE and IVUS (40 and 42 versus 25; P<0.001 each). In 4 patients with abdominal extension of the dissection, only IVUS was able to accurately identify the false lumen over the entire length of the diseased aorta. TEE was superior to IVUS and ANGIO in the detection of endoleaks (5 versus 0 and 1; P<0.05 each). Intraprocedural ANGIO, TEE, and IVUS had been performed without complications in all patients.
CONCLUSIONS: TEE in conjunction with ANGIO appears to be advantageous and adds incremental information to safely guide stent-graft placement in type-B aortic dissection. Additional use of IVUS was found to be helpful in patients with complex anatomy and abdominal extension of the dissection.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16159828     DOI: 10.1161/CIRCULATIONAHA.104.525972

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  11 in total

Review 1.  [Perioperative transesophageal echocardiography in non-cardiac surgery. Update].

Authors:  D Wally; C Velik-Salchner
Journal:  Anaesthesist       Date:  2015-09       Impact factor: 1.041

2.  Acute Type B Dissection Causing Collapse of EVAR Endograft and Iliac Limb Occlusion.

Authors:  Nathan K Itoga; Tiffany Wu; Michael D Dake; Ronald L Dalman; Jason T Lee
Journal:  Ann Vasc Surg       Date:  2017-07-21       Impact factor: 1.466

3.  Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: A case report.

Authors:  Xu-Ran Li; Yuan-Hao Tong; Xiao-Qiang Li; Chang-Jian Liu; Chen Liu; Zhao Liu
Journal:  World J Clin Cases       Date:  2020-03-06       Impact factor: 1.337

4.  [Stent graft of the thoracic aorta].

Authors:  C A Nienaber; I Akin; S Kische; H Ince; T Chatterjee
Journal:  Internist (Berl)       Date:  2013-05       Impact factor: 0.743

5.  Endovascular treatment of acute type B dissection complicating aortic coarctation.

Authors:  Seyed Ebrahim Kassaian; Kyomars Abbasi; Mehdi Mousavi; Mohammad Sahebjam
Journal:  Tex Heart Inst J       Date:  2013

6.  Effect of Intravascular Ultrasound-assisted Thoracic Endovascular Aortic Repair for "Complicated" Type B Aortic Dissection.

Authors:  Bao-Lei Guo; Zhen-Yux Shi; Da-Qiao Guo; Li-Xin Wang; Xiao Tang; Wei-Miao Li; Wei-Guo Fu
Journal:  Chin Med J (Engl)       Date:  2015-09-05       Impact factor: 2.628

Review 7.  Various Endoluminal Approaches Available for Treating Pathologies of the Aortic Arch.

Authors:  Muzaffar A Anwar; Mohammad Hamady
Journal:  Cardiovasc Intervent Radiol       Date:  2020-06-25       Impact factor: 2.740

8.  Aortic intervention guided by contrast-enhanced transoesophageal ultrasound whist waiting for cardiac transplantation: a case report.

Authors:  Mireya Castro Verdes; Xun Yuan; Wei Li; Roxy Senior; Christoph A Nienaber
Journal:  Eur Heart J Case Rep       Date:  2020-12-12

9.  Intraoperative antegrade intravascular ultrasound examination in acute type A aortic dissection with suspected visceral malperfusion.

Authors:  Mehmet Alagoz; Yuki Ikeno; Akiko Tanaka; Anthony L Estrera; Rana O Afifi
Journal:  JTCVS Tech       Date:  2021-09-02

10.  Alternative management of proximal aortic dissection: concept and application.

Authors:  Xun Yuan; Andreas Mitsis; David Mozalbat; Christoph A Nienaber
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-12-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.