Literature DB >> 16159125

Determination of parabens in pharmaceutical formulations by solid-phase microextraction-ion mobility spectrometry.

John K Lokhnauth1, Nicholas H Snow.   

Abstract

Solid-phase microextraction (SPME) coupled with ion mobility spectrometry (IMS) was used for the detection and quantitation of 4-hydroxybenzoate preservatives, methylparaben, ethylparaben, propylparaben, and butylparaben, in commercial pharmaceutical products. For the first time, SPME-IMS is described for the simultaneous detection, separation, and quantitation of multiple analytes in complex matrixes. The parabens are extracted from the samples using SPME, and the analytes on the fiber are heated by the IMS desorber unit and vaporized into the drift tube. The four preservatives differing only by a methyl group were separated in less than 18 ms. The analytical procedure was optimized for fiber coating selection, extraction time, sample pH, sample volume, ionic strength, and IMS conditions. Separation characteristics such as resolution, theoretical plates, and drift times of the parabens were also evaluated based on the direct interfacing of SPME to IMS. The conditions were tested using six over-the-counter topical products containing various combinations of preservatives. Analysis of the samples by SPME-IMS using benzyl paraben as an internal standard yields good comparison to an HPLC method, thereby reinforcing the applicability of this technique as a method for routine analysis. Limits of detection were 10 ng/mL for methylparaben and ethylparaben and 5 ng/mL for propylparaben and butylparaben. Good linearity range and reproducibility of less than 8% were obtained.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16159125     DOI: 10.1021/ac0504013

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Urinary concentrations of environmental phenols and their associations with breast cancer incidence and mortality following breast cancer.

Authors:  Humberto Parada; Marilie D Gammon; Hope L Ettore; Jia Chen; Antonia M Calafat; Alfred I Neugut; Regina M Santella; Mary S Wolff; Susan L Teitelbaum
Journal:  Environ Int       Date:  2019-06-19       Impact factor: 9.621

2.  Microextraction of polycyclic aromatic hydrocarbons by using a stainless steel fiber coated with nanoparticles made from a porous aromatic framework.

Authors:  Wenchang Wang; Zhi Li; Wenjin Wang; Lihong Zhang; Shuaihua Zhang; Chun Wang; Zhi Wang
Journal:  Mikrochim Acta       Date:  2017-12-05       Impact factor: 5.833

3.  The use of shift reagents in ion mobility-mass spectrometry: studies on the complexation of an active pharmaceutical ingredient with polyethylene glycol excipients.

Authors:  Mark D Howdle; Christine Eckers; Alice M-F Laures; Colin S Creaser
Journal:  J Am Soc Mass Spectrom       Date:  2008-10-09       Impact factor: 3.109

4.  Cloud point extraction of parabens using non-ionic surfactant with cylodextrin functionalized ionic liquid as a modifier.

Authors:  Md Saleh Noorashikin; Muggundha Raoov; Sharifah Mohamad; Mhd Radzi Abas
Journal:  Int J Mol Sci       Date:  2013-12-17       Impact factor: 5.923

5.  Portable solid phase micro-extraction coupled with ion mobility spectrometry system for on-site analysis of chemical warfare agents and simulants in water samples.

Authors:  Liu Yang; Qiang Han; Shuya Cao; Jie Yang; Junchao Yang; Mingyu Ding
Journal:  Sensors (Basel)       Date:  2014-11-06       Impact factor: 3.576