Literature DB >> 1615802

Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion.

P S Rao1, R Langhough, R H Beekman, T R Lloyd, E B Sideris.   

Abstract

Stretched diameter of the atrial septal defect (ASD), determined by balloon sizing at cardiac catheterization, is commonly used to select the sizes of the devices used for transcatheter closure of the secundum ASD. We have previously evaluated the utility of pulmonary/systemic flow ratio and angiographic and echocardiographic (echo) sizes of the ASD in estimating stretched ASD diameter in a group of 16 patients and determined that echo diameter had the best correlation with stretched diameter (r = 0.82; p less than 0.001). The stretched diameter can be estimated: 1.05 x echo diameter in millimeters + 5.49. In this study we have prospectively evaluated this formula in estimating the stretched ASD diameter by two-dimensional echo measurements obtained in two (long and short-axis) subcostal views in another group of 21 patients aged 2.5 to 29 years (median 4.5 years). The echo size of the ASD was 9.7 +/- 3.0 mm, whereas the measured stretched diameter was 15.3 +/- 4.0 mm. The predicted stretched ASD diameter was calculated according to the above formula and was 15.7 +/- 3.1 mm, not significantly different (p greater than 0.1) from the measured stretched diameter. The correlation between predicted and measured stretched ASD sizes was excellent (r = 0.9; p less than 0.001). The mean squared error was 2.4. The differences between measured and predicted values were within 2 mm in all but three patients. It is concluded that stretched ASD diameter can be estimated accurately by two-dimensional subcostal echo measurements, which in turn could be used for selection of device size for occlusion of the ASD.

Entities:  

Mesh:

Year:  1992        PMID: 1615802     DOI: 10.1016/0002-8703(92)90937-q

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  13 in total

1.  Percutaneous closure of secundum atrial septal defect with a new self centering device ("angel wings").

Authors:  C Rickers; C Hamm; H Stern; T Hofmann; O Franzen; R Schräder; H Sievert; D Schranz; I Michel-Behnke; J Vogt; D Kececioglu; W Sebening; A Eicken; H Meyer; W Matthies; F Kleber; J Hug; J Weil
Journal:  Heart       Date:  1998-11       Impact factor: 5.994

2.  Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children.

Authors:  G Hausdorf; M Schneider; B Franzbach; C Kampmann; K Kargus; B Goeldner
Journal:  Heart       Date:  1996-01       Impact factor: 5.994

3.  The Journey of an Indian Pediatric Cardiologist : Dr. K. C. Chaudhuri Lifetime Achievement Award/Oration at AIIMS, New Delhi, September 2017.

Authors:  P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2017-09-27       Impact factor: 1.967

Review 4.  Transcatheter occlusion of atrial septal defect and patent ductus arteriosus: now a reality in India.

Authors:  P S Rao
Journal:  Indian J Pediatr       Date:  1993 Sep-Oct       Impact factor: 1.967

5.  Sizing of atrial septal defects to predict successful closure with transcatheter cardioSEAL device.

Authors:  H G El-Said; L I Bezold; R G Grifka; R H Pignatelli; C J McMahon; D A Schutte; E O Smith; C E Mullins
Journal:  Tex Heart Inst J       Date:  2001

6.  Morphology of perforated atrial septal aneurysm suitable for closure by transcatheter device placement.

Authors:  P Ewert; F Berger; M Vogel; I Dähnert; V Alexi-Meshkishvili; P E Lange
Journal:  Heart       Date:  2000-09       Impact factor: 5.994

7.  Right to left shunt through interatrial septal defects in patients with congenital heart disease: results of interventional closure.

Authors:  G Agnoletti; Y Boudjemline; P Ou; D Bonnet; D Sidi
Journal:  Heart       Date:  2005-11-03       Impact factor: 5.994

8.  Occlusion of congenital ventricular septal defects by the buttoned device. "Buttoned device" Clinical Trials International Register.

Authors:  E B Sideris; K P Walsh; J L Haddad; C R Chen; S G Ren; H Kulkarni
Journal:  Heart       Date:  1997-03       Impact factor: 5.994

9.  Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects.

Authors:  Michael L O'Byrne; Andrew C Glatz; David J Goldberg; Russell Shinohara; Yoav Dori; Jonathan J Rome; Matthew J Gillespie
Journal:  Congenit Heart Dis       Date:  2014-09-16       Impact factor: 2.007

10.  A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Arezoo Zoroufian; Marat A Volman
Journal:  Cardiovasc J Afr       Date:  2013-06       Impact factor: 1.167