Literature DB >> 16157372

Contrast sonography, video densitometry and intervillous blood flow: a pilot project.

W H Barth1, D C McCurnin, K Dee Carey, G D V Hankins.   

Abstract

PURPOSE: To examine the feasibility of constructing time-intensity (TI) curves from the intervillous space with an intravascular ultrasound contrast agent and computer assisted video densitometry. STUDY
DESIGN: We sedated nine pregnant baboons, optimized the grey scale and color Doppler images of their placentas, and then fixed the transducers in place. For each injection of contrast, we recorded images on videotape without changing the ultrasound image processing functions. Video images were captured using a Macintosh personal computer equipped with a video-capture board using image analysis software (Image 1.4, W Rasband, NIH). For each injection, we sampled digitized images of a fixed region of interest at regular intervals. After computing the mean video density of each image, we used the sampling frequency to construct TI curves depicting any change over time as the contrast agents washed into and out of the intervillous space.
RESULTS: Three of four agents tested produced changes in the video density of the placenta. TI curves were established using both grey scale and color Doppler signal augmentation. As expected, intra-arterial agents produced rapid accumulation and decay. Intravenous agents produced more protracted effects secondary to bolus dilution and transit through the right heart and pulmonary vascular bed.
CONCLUSION: TI curves may be generated from the intervillous space with the use of a transpulmonary ultrasound contrast agent and video densitometry. If validated by further study, this may allow investigators to apply ultrasound and indicator-dilution theory to intervillous blood flow.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16157372     DOI: 10.1016/j.placenta.2005.07.007

Source DB:  PubMed          Journal:  Placenta        ISSN: 0143-4004            Impact factor:   3.481


  2 in total

1.  Contrast-enhanced ultrasound for the assessment of placental development and function.

Authors:  Victoria Hj Roberts; Antonio E Frias
Journal:  Biotechniques       Date:  2020-09-04       Impact factor: 1.993

2.  Real-time placental perfusion on contrast-enhanced ultrasound and parametric imaging analysis in rats at different gestation time and different portions of placenta.

Authors:  Yi-Jie Zhou; Man-Li Yuan; Rui Li; Li-Ping Zhu; Zhao-Hui Chen
Journal:  PLoS One       Date:  2013-04-01       Impact factor: 3.240