Literature DB >> 16157191

Variables influencing intravenous catheter insertion difficulty and failure: an analysis of 339 intravenous catheter insertions.

Ann F Jacobson1, Elizabeth H Winslow.   

Abstract

BACKGROUND: Inserting an intravenous catheter (IV) is one of the most frequently performed invasive procedures by nurses. Little research has been conducted on ways to reduce the difficulty and failure, and enhance the ease and success, of IV insertion. We conducted this study to determine variables associated with IV insertion difficulty, failure, and success, and to learn special techniques nurses use to facilitate IV insertion.
METHODS: Data were collected on 339 IV insertions in hospitalized patients by 34 registered nurses. The data included information about the nurse (eg, age, education, and self-rated IV insertion skill); the patient (eg, age and race); the IV (eg, site, gauge, and type); and the IV insertion, (eg, duration and difficulty). Data were analyzed to determine the effects of these variables on IV insertion outcome. In addition, nurses were asked to describe special techniques they used to facilitate IV insertion.
RESULTS: A total of 77% of the IV insertions were successful. Nurses who were older, had more years of experience, were certified in a specialty, and rated themselves higher in insertion skill had significantly more successful insertions than their younger and less-experienced and less-skilled counterparts (P < .001). Successful IV insertions were significantly faster (mean 32 seconds) than unsuccessful ones (mean 66 seconds) (P < .001), and were rated as significantly less difficult (P < .001). Failed IV insertions were associated with higher degrees of difficulty arising from vein variables, such as vein rolled or vein was resistant to puncture, and patient variables, such as tough or dark skin and patient movement. The nurses described a wide variety of techniques to facilitate insertion success. The most frequently mentioned were getting self and patient in a comfortable position, using mechanical stimulation such as tapping the vein, and stabilizing the vein.
CONCLUSION: Approximately one fourth of the 339 IV insertions in this study were unsuccessful. Repeated insertion attempts are painful and costly. This study identified nurse, patient, and IV variables associated with IV insertion success and failure. Future research is needed to confirm and expand these findings and to develop interventions to improve IV insertion skills and outcomes.

Entities:  

Mesh:

Year:  2005        PMID: 16157191     DOI: 10.1016/j.hrtlng.2005.04.002

Source DB:  PubMed          Journal:  Heart Lung        ISSN: 0147-9563            Impact factor:   2.210


  24 in total

Review 1.  Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis.

Authors:  Joon Min Park; Min Joung Kim; Hyeon Woo Yim; Won-Chul Lee; Hyunsuk Jeong; Na Jin Kim
Journal:  Eur J Pediatr       Date:  2016-10-26       Impact factor: 3.183

2.  Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

Authors:  Heidi L McNeely; Theresa L Ream; Jodi M Thrasher; Oliwier Dziadkowiec; Tiffany J Callahan
Journal:  J Spec Pediatr Nurs       Date:  2018-02-10       Impact factor: 1.260

3.  Portable robot for autonomous venipuncture using 3D near infrared image guidance.

Authors:  Alvin Chen; Kevin Nikitczuk; Jason Nikitczuk; Tim Maguire; Martin Yarmush
Journal:  Technology (Singap World Sci)       Date:  2013-09

4.  Sex differences in the prehospital management of out-of-hospital cardiac arrest.

Authors:  Bryn E Mumma; Temur Umarov
Journal:  Resuscitation       Date:  2016-06-11       Impact factor: 5.262

5.  Comparison of the tolerability of recombinant human hyaluronidase + normal saline and recombinant human hyaluronidase + lactated ringer's solution administered subcutaneously: A phase IV, double-blind, randomized pilot study in healthy volunteers.

Authors:  Samuel S Dychter; David Ebel; Tonya R Mead; Richard C Yocum
Journal:  Curr Ther Res Clin Exp       Date:  2009-12

6.  Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol.

Authors:  Peter J Carr; James C R Rippey; Marie L Cooke; Chrianna Bharat; Kevin Murray; Niall S Higgins; Aileen Foale; Claire M Rickard
Journal:  BMJ Open       Date:  2016-02-11       Impact factor: 2.692

7.  Knowledge Level on Administration of Chemotherapy through Peripheral and Central Venous Catheter among Oncology Nurses.

Authors:  Sevgisun Kapucu; Ayşe Özaydın Özkaraman; Neşe Uysal; Gulcan Bagcivan; Ferhan Çetin Şeref; Aygül Elöz
Journal:  Asia Pac J Oncol Nurs       Date:  2017 Jan-Mar

8.  Does Test-enhanced Learning Improve Success Rates of Ultrasound-guided Peripheral Intravenous Insertion? A Randomized Controlled Trial.

Authors:  Adam Slomer; Jordan Chenkin
Journal:  AEM Educ Train       Date:  2017-07-10

9.  Hyperspectral venous image quality assessment for optimum illumination range selection based on skin tone characteristics.

Authors:  Aamir Shahzad; Mohamad Naufal Saad; Nicolas Walter; Aamir Saeed Malik; Fabrice Meriaudeau
Journal:  Biomed Eng Online       Date:  2014-08-03       Impact factor: 2.819

10.  An observational study comparing the prototype device with the existing device for the effective visualization of invisible veins in elderly patients in Japan.

Authors:  Keiko Kimori; Junko Sugama; Toshio Nakatani; Kazuya Nakayama; Tosiaki Miyati; Hiromi Sanada
Journal:  SAGE Open Med       Date:  2015-11-27
View more