Literature DB >> 16155977

Assessment of microwave-assisted enzymatic digestion by measuring glycated hemoglobin A1c by mass spectrometry.

Hubert W Vesper1, Luchuan Mi, Archibold Enada, Gary L Myers.   

Abstract

Enzymatic digestion of proteins and analysis of the resulting peptides by mass spectrometry is an established approach in proteomics and in clinical and environmental chemistry. The long digestion times of several hours prevent the fast turnover of samples and results. Qualitative applications showed that microwave radiation profoundly shortens enzymatic digestion. However, its usefulness for quantitative applications had not been assessed. In this study, the microwave-assisted enzymatic digestion of hemoglobin at different temperatures, buffer concentrations, and digestion times was assessed and compared with conventional digestion for the proteolytic enzymes trypsin and Glu-C. A microwave-assisted enzymatic digestion method optimized for digestion time and temperature was applied for the analysis of glycated hemoglobin HbA1c and compared with a reference method. Using trypsin, complete digestion was obtained at 50 degrees C within 20 min. Under these conditions, the digestion efficiency was 20% higher than with conventional trypsin digestion. These effects were not observed with Glu-C as enzyme, probably because of the decreased stability of Glu-C at elevated temperatures in comparison with the trypsin used. The comparison of the optimized microwave-assisted digestion method using trypsin with the reference method for HbA1c using Glu-C gave a close correlation in the results (R2: 0.996). A significant bias of 0.33% HbA1c was observed, with higher values obtained with the microwave-assisted tryptic digest; this finding might have resulted from the use of a different enzyme. This study showed that microwave-assisted enzymatic digestion can substantially reduce digestion times to minutes and can be used in qualitative as well as quantitative applications. 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16155977     DOI: 10.1002/rcm.2135

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  Digestion of native proteins for proteomics using a thermocycler.

Authors:  Obolbek A Turapov; Galina V Mukamolova; Andrew R Bottrill; Michael K Pangburn
Journal:  Anal Chem       Date:  2008-06-26       Impact factor: 6.986

2.  Rapid method for sensitive screening of oligosaccharide epitopes in the lipooligosaccharide from Campylobacter jejuni strains isolated from Guillain-Barré syndrome and Miller Fisher syndrome patients.

Authors:  Monika Dzieciatkowska; Xin Liu; Astrid P Heikema; R Scott Houliston; Alex van Belkum; Elke K H Schweda; Michel Gilbert; James C Richards; Jianjun Li
Journal:  J Clin Microbiol       Date:  2008-08-27       Impact factor: 5.948

3.  Comparative evaluation of current peptide production platforms used in absolute quantification in proteomics.

Authors:  Hamid Mirzaei; Joshua K McBee; Julian Watts; Ruedi Aebersold
Journal:  Mol Cell Proteomics       Date:  2007-12-17       Impact factor: 5.911

4.  Antioxidative peptides derived from enzyme hydrolysis of bone collagen after microwave assisted acid pre-treatment and nitrogen protection.

Authors:  Yun-Jian Lin; Guo-Wei Le; Jie-Yun Wang; Ya-Xin Li; Yong-Hui Shi; Jin Sun
Journal:  Int J Mol Sci       Date:  2010-11-01       Impact factor: 5.923

5.  Can electromagnetic fields influence the structure and enzymatic digest of proteins? A critical evaluation of microwave-assisted proteomics protocols.

Authors:  Markus Damm; Christoph Nusshold; David Cantillo; Gerald N Rechberger; Karl Gruber; Wolfgang Sattler; C Oliver Kappe
Journal:  J Proteomics       Date:  2012-08-06       Impact factor: 4.044

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.