Literature DB >> 16155885

Ghost artifact removal using a parallel imaging approach.

Richard Winkelmann1, Peter Börnert, Olaf Dössel.   

Abstract

Parallel imaging techniques, which use several receive coils simultaneously, have been shown to enable a significant scan time reduction by subsampling k-space. Nevertheless, the data acquired with multiple coils in parallel exhibit some redundancy if the number of receive coils exceeds the subsampling factor. This redundancy leads to an overdetermination of the reconstruction problem, which is generally used to optimize the signal-to-noise ratio (SNR). However, it can yield further information about the quality of the reconstructed image, and can thus be used to identify and correct image artifacts. While some known approaches try to solve this problem in k-space, this study addresses it in the spatial domain and uses a modified SENSE reconstruction to reduce or completely remove ghost-type artifacts arising from processes such as motion or flow during data acquisition. Phantom and in vivo studies show significant improvements in image quality after correction, and serve as a basis for the discussion of the performance and limitations of this new approach. Copyright 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16155885     DOI: 10.1002/mrm.20640

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

Review 1.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

2.  Robust GRAPPA reconstruction and its evaluation with the perceptual difference model.

Authors:  Donglai Huo; David L Wilson
Journal:  J Magn Reson Imaging       Date:  2008-06       Impact factor: 4.813

3.  Pseudolesions arising from unfolding artifacts in diffusion imaging with use of parallel acquisition: origin and remedies.

Authors:  M-C Chou; C-Y Wang; H-S Liu; H-W Chung; C-Y Chen
Journal:  AJNR Am J Neuroradiol       Date:  2007 Jun-Jul       Impact factor: 3.825

4.  Parallel reconstruction using null operations.

Authors:  Jian Zhang; Chunlei Liu; Michael E Moseley
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

Review 5.  A half-century of innovation in technology-preparing MRI for the 21st century.

Authors:  Peter Börnert; David G Norris
Journal:  Br J Radiol       Date:  2020-06-15       Impact factor: 3.039

Review 6.  Whole-body diffusion-weighted and proton imaging: a review of this emerging technology for monitoring metastatic cancer.

Authors:  Michael A Jacobs; Li Pan; Katarzyna J Macura
Journal:  Semin Roentgenol       Date:  2009-04       Impact factor: 0.800

7.  Identification of ghost artifact using texture analysis in pediatric spinal cord diffusion tensor images.

Authors:  Mahdi Alizadeh; Chris J Conklin; Devon M Middleton; Pallav Shah; Sona Saksena; Laura Krisa; Jürgen Finsterbusch; Scott H Faro; M J Mulcahey; Feroze B Mohamed
Journal:  Magn Reson Imaging       Date:  2017-11-15       Impact factor: 2.546

8.  Suppressing multi-channel ultra-low-field MRI measurement noise using data consistency and image sparsity.

Authors:  Fa-Hsuan Lin; Panu T Vesanen; Yi-Cheng Hsu; Jaakko O Nieminen; Koos C J Zevenhoven; Juhani Dabek; Lauri T Parkkonen; Juha Simola; Antti I Ahonen; Risto J Ilmoniemi
Journal:  PLoS One       Date:  2013-04-23       Impact factor: 3.240

9.  Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Authors:  Liheng Guo; J Andrew Derbyshire; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

10.  Reducing ghosting due to k-space discontinuities in fast spin echo (FSE) imaging by a new combination of k-space ordering and parallel imaging.

Authors:  David W Carmichael; David L Thomas; Roger J Ordidge
Journal:  J Magn Reson       Date:  2009-06-21       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.