| Literature DB >> 16150657 |
Gholamreza Bahrami1, Bahareh Mohammadi, Shahla Mirzaeei, Amir Kiani.
Abstract
A rapid and sensitive high-performance liquid chromatographic method was validated and described for determination of atorvastatin in human serum. Following liquid-liquid extraction of the drug and an internal standard (sodium diclofenac), chromatographic separation was accomplished using C18 analytical column with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0) and methanol (33:67, v/v). Atorvastatin and the internal standard were detected by ultraviolet absorbance at 247 nm. The average recoveries of the drug and internal standard were 95 and 80%, respectively. The lower limits of detection and quantification were 1 and 4 ng/ml, respectively, and the calibration curves were linear over a concentration range of 4-256 ng/ml of atorvastatin in human serum. The analysis performance was studied and the method was applied in a randomized cross-over bioequivalence study of two different atorvastatin preparations in 12 healthy volunteers.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16150657 DOI: 10.1016/j.jchromb.2005.08.008