OBJECTIVE: To test the agreement between observers and reproducibility of a technique to display standard cardiac views of the left and right ventricular outflow tracts from four-dimensional volume datasets acquired with Spatiotemporal Image Correlation (STIC). METHODS: A technique was developed to obtain dynamic multiplanar images of the left ventricular outflow tract (LVOT) and right ventricular outflow tract (RVOT) from volume datasets acquired with STIC. Volume datasets were acquired from fetuses with normal cardiac anatomy. Twenty volume datasets of satisfactory quality were pre-selected by one investigator. The data was randomly assigned for a blinded review by two independent observers with previous experience in fetal echocardiography. Only one volume dataset was used for each fetus. After a training session, the observers obtained standardized cardiac views of the LVOT and RVOT, which were scored on a scale of 1 to 5, based on diagnostic value and image quality (1=unacceptable, 2=marginal, 3=acceptable, 4=good, and 5=excellent). Median scores and interquartile range, as well as inter- and intraobserver agreement were calculated for each view. RESULTS: The mean menstrual age at the time of volume acquisition was 25.5+/-4.5 weeks. Median scores (interquartile range) for LVOT images, obtained by the first and second observers, were 3.5 (2.25-5.00) and 4 (3.00-5.00), respectively. The median scores (interquartile range) for RVOT images obtained by the first and second observers were 3 (3.00-5.00) and 3 (2.00-4.00), respectively. The interobserver intraclass correlation coefficient for the LVOT was 0.693 (95% CI 0.380-0.822), and 0.696 (95% CI 0.382-0.866) for the RVOT. For the intraobserver agreement analysis, observer 1 gave higher scores to the LVOT the second time the volumes were analyzed [LVOT: 3.50 (2.25-5.00) vs. 5.00 (4.00-5.00, p=0.008)]. CONCLUSION: STIC can be reproducibly used to evaluate fetal cardiac outflow tracts by independent examiners. Slightly better image quality rating scores during the intraobserver variability trial suggests the presence of a learning curve for the manipulation and analysis of volume data obtained by STIC.
RCT Entities:
OBJECTIVE: To test the agreement between observers and reproducibility of a technique to display standard cardiac views of the left and right ventricular outflow tracts from four-dimensional volume datasets acquired with Spatiotemporal Image Correlation (STIC). METHODS: A technique was developed to obtain dynamic multiplanar images of the left ventricular outflow tract (LVOT) and right ventricular outflow tract (RVOT) from volume datasets acquired with STIC. Volume datasets were acquired from fetuses with normal cardiac anatomy. Twenty volume datasets of satisfactory quality were pre-selected by one investigator. The data was randomly assigned for a blinded review by two independent observers with previous experience in fetal echocardiography. Only one volume dataset was used for each fetus. After a training session, the observers obtained standardized cardiac views of the LVOT and RVOT, which were scored on a scale of 1 to 5, based on diagnostic value and image quality (1=unacceptable, 2=marginal, 3=acceptable, 4=good, and 5=excellent). Median scores and interquartile range, as well as inter- and intraobserver agreement were calculated for each view. RESULTS: The mean menstrual age at the time of volume acquisition was 25.5+/-4.5 weeks. Median scores (interquartile range) for LVOT images, obtained by the first and second observers, were 3.5 (2.25-5.00) and 4 (3.00-5.00), respectively. The median scores (interquartile range) for RVOT images obtained by the first and second observers were 3 (3.00-5.00) and 3 (2.00-4.00), respectively. The interobserver intraclass correlation coefficient for the LVOT was 0.693 (95% CI 0.380-0.822), and 0.696 (95% CI 0.382-0.866) for the RVOT. For the intraobserver agreement analysis, observer 1 gave higher scores to the LVOT the second time the volumes were analyzed [LVOT: 3.50 (2.25-5.00) vs. 5.00 (4.00-5.00, p=0.008)]. CONCLUSION: STIC can be reproducibly used to evaluate fetal cardiac outflow tracts by independent examiners. Slightly better image quality rating scores during the intraobserver variability trial suggests the presence of a learning curve for the manipulation and analysis of volume data obtained by STIC.
Authors: M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade Journal: Ultrasound Obstet Gynecol Date: 2016-03-10 Impact factor: 7.299
Authors: Jimmy Espinoza; Sonia S Hassan; Francesca Gotsch; Juan Pedro Kusanovic; Wesley Lee; Offer Erez; Luís F Gonçalves; Mary Lou Schoen; Roberto Romero Journal: J Ultrasound Med Date: 2007-11 Impact factor: 2.153
Authors: Neil Hamill; Roberto Romero; Sonia S Hassan; Wesley Lee; Stephen A Myers; Pooja Mittal; Juan Pedro Kusanovic; Tinnakorn Chaiworapongsa; Edi Vaisbuch; Jimmy Espinoza; Francesca Gotsch; Angela Carletti; Luís F Gonçalves; Lami Yeo Journal: J Ultrasound Med Date: 2009-10 Impact factor: 2.153
Authors: Dariusz Kozłowski; Adam Kosiński; Alicja Dąbrowska-Kugacka; Ewa Lewicka-Nowak; Maria Dudziak; Marek Grzybiak; Grzegorz Raczak Journal: Arch Med Sci Date: 2010-10-26 Impact factor: 3.318
Authors: David F A Lloyd; Kuberan Pushparajah; John M Simpson; Joshua F P van Amerom; Milou P M van Poppel; Alexander Schulz; Bernard Kainz; Maria Deprez; Maelene Lohezic; Joanna Allsop; Sujeev Mathur; Hannah Bellsham-Revell; Trisha Vigneswaran; Marietta Charakida; Owen Miller; Vita Zidere; Gurleen Sharland; Mary Rutherford; Joseph V Hajnal; Reza Razavi Journal: Lancet Date: 2019-03-22 Impact factor: 202.731