Respiratory mechanics in mechanically ventilated newborns: a comparison between passive inflation and occlusion methods.

L Storme1, Y Riou, F Leclerc, N Kacet, J P Dubos, C Gremillet, S Rousseau, P Lequien.   

Abstract

A passive inflation method was described for measuring total respiratory elastance and resistance during mechanical ventilation in adult patients (Rossi et al., J Appl Physiol 58:1849, 1985). We applied this method to preterm and full-term mechanically ventilated newborn infants and we compared the results with those obtained by the occlusion method. We performed 37 tests in 16 newborn infants (B.W. 880-4,500 g; G.A. 28-42 weeks), between 1 and 45 days of postnatal age, ventilated with a Servo Ventilator 900C, set in controlled-volume mode. Flow was measured through a pneumotachograph inserted between the endotracheal tube (ETT) and the breathing circuit, tidal volume by integration of flow and airway pressure directly at the airway opening. Flow, volume, and pressure were recorded on an X/Y plotter to obtain pressure-volume (P/V), flow-volume (V/V) loops, and pressure-time curves. Occlusion was performed by using the end-inspiratory and the end-expiratory pause buttons of the ventilator. Analysis of P/V and V/V loops provided respiratory system compliance (Crs, infl.), resistance (Rrs, infl.), and "intrinsic positive end-expiratory pressure" (PEEPi, infl.). These values were compared with Crs, occl., Rrs, occl., and PEEPi, occl. measured by the occlusion method. The measurements were well correlated (Crs, infl./Crs, occl.: r = 0.90; Rrs, infl./Rrs, occl.: r = 0.91; PEEPi, infl./PEEPi, occl.: r = 0.91). Rrs, infl./Rrs, occl. and PEEPi, infl./PEEPi, occl. did not differ significantly. However, Crs, occl. was 15% higher than Crs, infl. (P less than 0.01). The passive inflation method is simple to use and well tolerated in preterm and full-term ventilated newborn infants, it provides accurate results, and can be a good alternative to occlusion methods. It requires, however, a constant inflation flow and adaptation to the ventilator.

Entities:  

Mesh:

Year:  1992        PMID: 1614746     DOI: 10.1002/ppul.1950120403

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  3 in total

1.  Lung liquid clearance in preterm lambs assessed by magnetic resonance imaging.

Authors:  Ali Houeijeh; Pierre Tourneux; Sébastien Mur; Estelle Aubry; Romain Viard; Dyuti Sharma; Laurent Storme
Journal:  Pediatr Res       Date:  2017-02-07       Impact factor: 3.756

Review 2.  Lung function testing--useless in ventilated newborns?

Authors:  O Hjalmarson
Journal:  Eur J Pediatr       Date:  1994       Impact factor: 3.183

3.  Effect of Tiotropium Soft Mist Inhalers on Dynamic Changes in Lung Mechanics of Patients with Chronic Obstructive Pulmonary Disease Receiving Mechanical Ventilation: A Prospective Pilot Study.

Authors:  Pin-Kuei Fu; Yu-Feng Wei; Chau-Chyun Sheu; Chen-Yu Wang; Chi-Kuei Hsu; Chia-Min Chen; Wei-Chih Chen; Kuang-Yao Yang
Journal:  Pharmaceutics       Date:  2020-12-31       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.