Literature DB >> 16145292

Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study.

Xu He1, Ji Hoon Shin, Hyo-Cheol Kim, Cheol Woong Woo, Sung Ha Woo, Won-Chan Choi, Jong-Gyu Kim, Jin-Oh Lim, Tae-Hyung Kim, Chang Jin Yoon, Weechang Kang, Ho-Young Song.   

Abstract

OBJECTIVE: We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study.
MATERIALS AND METHODS: The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group ll was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded.
RESULTS: Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (p < 0.001). A significant difference was also found between group III and IV for both phantoms (p < 0.001).
CONCLUSION: The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body.

Entities:  

Mesh:

Year:  2005        PMID: 16145292      PMCID: PMC2685040          DOI: 10.3348/kjr.2005.6.3.167

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  17 in total

Review 1.  Advances in gastrointestinal intervention: the treatment of gastroduodenal and colorectal obstructions with metallic stents.

Authors:  M A Mauro; R E Koehler; T H Baron
Journal:  Radiology       Date:  2000-06       Impact factor: 11.105

Review 2.  Gastrointestinal stenting.

Authors:  C L Zollikofer; R Jost; E Schoch; M Decurtins
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

3.  Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture.

Authors:  J M Lee; Y M Han; C S Kim; S Y Lee; S T Lee; D H Yang
Journal:  Clin Radiol       Date:  2001-07       Impact factor: 2.350

4.  Malignant obstruction of gastric outlet and duodenum: palliation with flexible covered metallic stents.

Authors:  K B Park; Y S Do; W K Kang; S W Choo; Y H Han; S W Suh; S J Lee; K S Park; I W Choo
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

5.  Transhepatic insertion of a metallic stent for the relief of malignant afferent loop obstruction.

Authors:  D G Caldicott; P Ziprin; R Morgan
Journal:  Cardiovasc Intervent Radiol       Date:  2000 Mar-Apr       Impact factor: 2.740

6.  Self-expanding coil stent with a long delivery system for palliation of unresectable malignant gastric outlet obstruction: a prospective study.

Authors:  J H Kim; B M Yoo; K J Lee; K B Hahm; S W Cho; J J Park; S S Kim; H C Park; J H Kim
Journal:  Endoscopy       Date:  2001-10       Impact factor: 10.093

7.  Expandable metal stents for the palliation of malignant gastroduodenal obstruction.

Authors:  R Razzaq; H U Laasch; R England; A Marriott; D Martin
Journal:  Cardiovasc Intervent Radiol       Date:  2001 Sep-Oct       Impact factor: 2.740

8.  Malignant gastric and duodenal stenosis: palliation by peroral implantation of a self-expanding metallic stent.

Authors:  I T Pinto
Journal:  Cardiovasc Intervent Radiol       Date:  1997 Nov-Dec       Impact factor: 2.740

9.  Malignant gastroduodenal obstructions: treatment by means of a covered expandable metallic stent-initial experience.

Authors:  G S Jung; H Y Song; S G Kang; J D Huh; S J Park; J Y Koo; Y D Cho
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

10.  Palliation of malignant gastric and small intestinal strictures with self-expandable metal stents.

Authors:  M R Yates; D E Morgan; T H Baron
Journal:  Endoscopy       Date:  1998-03       Impact factor: 10.093

View more
  1 in total

1.  Modelling and manufacturing of 3D-printed, patient-specific, and anthropomorphic gastric phantoms: a pilot study.

Authors:  Jinhee Kwon; Joonmyeong Choi; Sangwook Lee; Minkyeong Kim; Yoon Kyung Park; Do Hyun Park; Namkug Kim
Journal:  Sci Rep       Date:  2020-11-04       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.