Literature DB >> 16144816

Reduced sampling schedule for the glucose minimal model: importance of Bayesian estimation.

Paolo Magni1, Giovanni Sparacino, Riccardo Bellazzi, Claudio Cobelli.   

Abstract

The minimal model (MM) of glucose kinetics during an intravenous glucose tolerance test (IVGTT) is widely used in clinical studies to measure metabolic indexes such as glucose effectiveness (S(G)) and insulin sensitivity (S(I)). The standard (frequent) IVGTT sampling schedule (FSS) for MM identification consists of 30 points over 4 h. To facilitate clinical application of the MM, reduced sampling schedules (RSS) of 13-14 samples have also been derived for normal subjects. These RSS are especially appealing in large-scale studies. However, with RSS, the precision of S(G) and S(I) estimates deteriorates and, in certain cases, becomes unacceptably poor. To overcome this difficulty, population approaches such as the iterative two-stage (ITS) approach have been recently proposed, but, besides leaving some theoretical issues open, they appear to be oversized for the problem at hand. Here, we show that a Bayesian methodology operating at the single individual level allows an accurate determination of MM parameter estimates together with a credible measure of their precision. Results of 16 subjects show that, in passing from FSS to RSS, there are no significant changes of point estimates in nearly all of the subjects and that only a limited deterioration of parameter precision occurs. In addition, in contrast with the previously proposed ITS method, credible confidence intervals (e.g., excluding negative values) are obtained. They can be crucial for a subsequent use of the estimated MM parameters, such as in classification, clustering, regression, or risk analysis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16144816     DOI: 10.1152/ajpendo.00241.2003

Source DB:  PubMed          Journal:  Am J Physiol Endocrinol Metab        ISSN: 0193-1849            Impact factor:   4.310


  2 in total

1.  Dependence of treatment planning accuracy in peptide receptor radionuclide therapy on the sampling schedule.

Authors:  Christian Maaß; Jan Philipp Sachs; Deni Hardiansyah; Felix M Mottaghy; Peter Kletting; Gerhard Glatting
Journal:  EJNMMI Res       Date:  2016-03-25       Impact factor: 3.138

Review 2.  Next-generation, personalised, model-based critical care medicine: a state-of-the art review of in silico virtual patient models, methods, and cohorts, and how to validation them.

Authors:  J Geoffrey Chase; Jean-Charles Preiser; Jennifer L Dickson; Antoine Pironet; Yeong Shiong Chiew; Christopher G Pretty; Geoffrey M Shaw; Balazs Benyo; Knut Moeller; Soroush Safaei; Merryn Tawhai; Peter Hunter; Thomas Desaive
Journal:  Biomed Eng Online       Date:  2018-02-20       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.