Literature DB >> 16142481

Proximal stent fixation of fractured coils: technical note.

Ansgar Schütz1, László Solymosi, Giles H Vince, Martin Bendszus.   

Abstract

Coil fracture represents a serious device-related complication during coil embolisation of intracranial aneurysms. If the coil cannot be retrieved completely, the loose end floating in the parent vessel can prolapse into the distal part of the vessel and may cause occlusion and brain infarction. We present a new technique in which the loose end of the fractured coil is fixed with a stent at the proximal parent vessel wall. Herniation of the loose coil end to the distal part of the vessel with potential vessel occlusion is therefore prevented. This procedure was technically feasible in all cases and no clinical complications were encountered. We suggest this new technique as a treatment option in cases of fractured coils.

Entities:  

Mesh:

Year:  2005        PMID: 16142481     DOI: 10.1007/s00234-005-1430-4

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  7 in total

1.  Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients.

Authors:  F Viñuela; G Duckwiler; M Mawad
Journal:  J Neurosurg       Date:  1997-03       Impact factor: 5.115

2.  Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion-weighted imaging.

Authors:  G Rordorf; R J Bellon; R E Budzik; J Farkas; G F Reinking; R S Pergolizzi; M Ezzeddine; A M Norbash; R G Gonzalez; C M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2001-01       Impact factor: 3.825

3.  International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial.

Authors:  Andrew Molyneux; Richard Kerr; Irene Stratton; Peter Sandercock; Mike Clarke; Julia Shrimpton; Rury Holman
Journal:  Lancet       Date:  2002-10-26       Impact factor: 79.321

4.  [Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases].

Authors:  J Moret; C Cognard; A Weill; L Castaings; A Rey
Journal:  J Neuroradiol       Date:  1997-06       Impact factor: 3.447

5.  Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results.

Authors:  S C Standard; T D Chavis; A K Wakhloo; A Ahuja; L R Guterman; L N Hopkins
Journal:  Neurosurgery       Date:  1994-11       Impact factor: 4.654

6.  Endovascular extraction of malpositioned fibered platinum microcoils from the aneurysm sac during endovascular therapy.

Authors:  G H Zoarski; H M Bear; J C Clouston; J Ragheb
Journal:  AJNR Am J Neuroradiol       Date:  1997-04       Impact factor: 3.825

7.  Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms.

Authors:  David Fiorella; Felipe C Albuquerque; Patrick Han; Cameron G McDougall
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

  7 in total
  15 in total

1.  Use of wire as a snare for endovascular retrieval of displaced or stretched coils: rescue from a technical complication.

Authors:  Chang-Young Lee
Journal:  Neuroradiology       Date:  2010-03-30       Impact factor: 2.804

2.  Coil herniation following intra-arterial verapamil infusion for the treatment of cerebral vasospasm: Case report and literature review.

Authors:  Stephanie H Chen; Ramesh Grandhi; Christopher P Deibert; Tudor G Jovin; Paul A Gardner; Andrew F Ducruet
Journal:  Interv Neuroradiol       Date:  2015-05-01       Impact factor: 1.610

3.  Magnetic wires: A novel design for neuroendovascular coil retrieval.

Authors:  Lingyun Zhang; Yugang Jiang
Journal:  Exp Ther Med       Date:  2018-07-23       Impact factor: 2.447

4.  Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

Authors:  Travis R Ladner; Lucy He; Brandon J Davis; Michael T Froehler; J Mocco
Journal:  BMJ Case Rep       Date:  2015-03-18

5.  Mini-arteriotomy to remove misplaced Gugliemi detachable coils: case report and technical note.

Authors:  Guo-Liang Jin; Zi-Gang Yuan
Journal:  Int J Clin Exp Med       Date:  2015-09-15

6.  Delayed herniation of coil loop and spontaneous reposition in a superior cerebellar artery aneurysm.

Authors:  Ki Bum Sim; Ji Kang Park; O-Ki Kwon; Jung Cheol Park
Journal:  Neurointervention       Date:  2011-02-28

7.  Additional Rescue Stent Placement for Stabilization of a Prolapsed Coil during Stent-assisted Coil Embolization of a Wide-Neck Intracranial Aneurysm.

Authors:  N Sourour; F Góngora-Rivera; A Biondi
Journal:  Interv Neuroradiol       Date:  2006-12-13       Impact factor: 1.610

8.  Retrieval of migrated coils with stent retrievers: an animal study.

Authors:  O Nikoubashman; R Pjontek; M-A Brockmann; R Tolba; M Wiesmann
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-12       Impact factor: 3.825

9.  Stent retriever use for retrieval of displaced microcoils: a consecutive case series.

Authors:  T M Leslie-Mazwi; M Heddier; H Nordmeyer; M Stauder; A Velasco; P J Mosimann; R Chapot
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-13       Impact factor: 3.825

10.  Stent management of coil herniation in embolization of internal carotid aneurysms.

Authors:  C-B Luo; F-C Chang; M M-H Teng; W-Y Guo; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.