Literature DB >> 16137087

Periimplant soft tissue barrier at experimental one-piece mini-implants with different surface topography in humans: A light-microscopic overview and histometric analysis.

Roland Glauser1, Peter Schüpbach, Jan Gottlow, Christoph H F Hämmerle.   

Abstract

BACKGROUND: Following connection to the oral cavity, osseointegrated dental implants and surrounding tissues are exposed to microbiologic and biomechanical challenges. The establishment of a firm functional periimplant soft tissue barrier (PSTB) is considered to be important to protect the implant's interface from invasion of bacteria. The current knowledge on the histologic architecture of the PSTB is mainly based on animal experiments.
PURPOSE: The aim of this study was to histologically characterize the PSTB formed in humans around experimental one-piece mini-implants with different surface topography.
MATERIALS AND METHODS: Five patients received a total of 12 experimental titanium, one-piece mini-implants with an oxidized (n = 4), an acid-etched (n = 4), or a machined (n = 4) surface distal to therapeutic implants. Following transmucosal healing of 8 weeks and at abutment connection of the regular implants, the mini-implants were harvested with a layer of surrounding hard and soft tissue. The specimens were fixed and processed for histologic sectioning according to standard procedures. The most central bucco-oral section cut in the long axis was used for morphologic analyses of the PSTB. The vertical soft tissue morphology was quantified using histometric measurements.
RESULTS: The overall height of the soft tissue, that is, the biologic width, was around 4 to 4.5 mm and consisted of an epithelial and a supracrestal connective tissue barrier. The junctional epithelium established the attachment to the implant surface, whereas the collagen fibers and fibroblasts of the connective tissue seal were oriented parallel to the implant. The epithelial attachment was shorter at the oxidized and acid-etched surfaces compared with the machined surfaces. Accordingly, the oxidized and acid-etched mini-implants exhibited a longer zone of connective tissue seal.
CONCLUSION: The periimplant soft tissue formed at the experimental one-piece mini-implants in humans was of a character similar to that described in animal studies. The oxidized and acid-etched implants revealed less epithelial downgrowth and longer connective tissue seal than machined implants.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16137087     DOI: 10.1111/j.1708-8208.2005.tb00074.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  19 in total

1.  A Comparative Study of Clinical Parameters in Submerged and Non submerged Implants.

Authors:  Parviz Torkzaban; Seyed Reza Arabi; Ghodratollah Roshanaei; Mohsen Rostami; Sara Soheilifar
Journal:  J Clin Diagn Res       Date:  2015-03-01

2.  In vitro assessment of the soft tissue/implant interface using porcine gingival explants.

Authors:  Aous A Abdulmajeed; Jaana Willberg; Stina Syrjänen; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

3.  Impaired Differentiation of Langerhans Cells in the Murine Oral Epithelium Adjacent to Titanium Dental Implants.

Authors:  Oded Heyman; Noam Koren; Gabriel Mizraji; Tal Capucha; Sharon Wald; Maria Nassar; Yaara Tabib; Lior Shapira; Avi-Hai Hovav; Asaf Wilensky
Journal:  Front Immunol       Date:  2018-08-15       Impact factor: 7.561

4.  Soft tissue cell adhesion to titanium abutments after different cleaning procedures: preliminary results of a randomized clinical trial.

Authors:  L Canullo; D Penarrocha-Oltra; S Marchionni; L Bagán; M-A Peñarrocha-Diago; C Micarelli
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-03-01

5.  Evaluation of a novel oral mucosa in vitro implantation model for analysis of molecular interactions with dental abutment surfaces.

Authors:  Sanne Roffel; Gang Wu; Ivana Nedeljkovic; Michael Meyer; Tojo Razafiarison; Susan Gibbs
Journal:  Clin Implant Dent Relat Res       Date:  2019-03-12       Impact factor: 3.932

6.  Fibroblast Interaction with Different Abutment Surfaces: In Vitro Study.

Authors:  Luigi Canullo; Tullio Genova; Esperanza Gross Trujillo; Guillermo Pradies; Sara Petrillo; Maurizio Muzzi; Stefano Carossa; Federico Mussano
Journal:  Int J Mol Sci       Date:  2020-03-11       Impact factor: 5.923

7.  Effects of titania nanotubes with or without bovine serum albumin loaded on human gingival fibroblasts.

Authors:  Xiangning Liu; Xiaosong Zhou; Shaobing Li; Renfa Lai; Zhiying Zhou; Ye Zhang; Lei Zhou
Journal:  Int J Nanomedicine       Date:  2014-03-06

8.  Biological width around one- and two-piece implants retrieved from human jaws.

Authors:  Ricardo Judgar; Gabriela Giro; Elton Zenobio; Paulo G Coelho; Magda Feres; Jose A Rodrigues; Carlo Mangano; Giovanna Iezzi; Adriano Piattelli; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

9.  Improved fibroblast functionalities by microporous pattern fabricated by microelectromechanical systems.

Authors:  Hongbo Wei; Lingzhou Zhao; Bangdao Chen; Shizhu Bai; Yimin Zhao
Journal:  Int J Mol Sci       Date:  2014-07-22       Impact factor: 5.923

Review 10.  Effects of modified abutment characteristics on peri-implant soft tissue health: A systematic review and meta-analysis.

Authors:  Ignacio Sanz-Martín; Ignacio Sanz-Sánchez; Ana Carrillo de Albornoz; Elena Figuero; Mariano Sanz
Journal:  Clin Oral Implants Res       Date:  2017-10-26       Impact factor: 5.977

View more