Literature DB >> 16136527

Coupling on-chip solid-phase extraction to electrospray mass spectrometry through an integrated electrospray tip.

Yanou Yang1, Chen Li, Kelvin H Lee, Harold G Craighead.   

Abstract

We report the integration of solid-phase extraction (SPE) with mass spectrometry (MS) through an on-chip electrospray tip for sample precleaning and preconcentration. An in situ polymerized alkylacrylate-based monolithic column was used as the stationary phase for the on-chip SPE. Each microchip consists of two sets of microchannels and their respective integrated electrospray tips, with a common gold electrode. After the microchip was fabricated from cycloolefin polymer by hot embossing, thermal bonding, and annealing steps, a mixture of monomers and porogenic solvents was pumped into the microchannels and certain areas of the main microchannels were exposed to UV irradiation through a mask. The resulting porous monolithic beds that were polymerized from different compositions of the mixture were characterized by scanning electron microscopy. The microchip containing the monolithic column was then interfaced to an ion trap (IT) mass spectrometer by modifying a commercially available interfacing system. Makeup solution from the side channel was infused concurrently with the solution flowing into the main channel, and the mixture of these two solutions was sprayed into the MS orifice. Both the adsorption and elution of a pharmaceutical test compound, imipramine, to and from the on-chip SPE columns were monitored by MS. The potential application of this device for sample cleanup was demonstrated by pretreatment of urine samples spiked with imipramine.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16136527     DOI: 10.1002/elps.200500121

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  8 in total

1.  Fabrication of a gel particle array in a microfluidic device for bioassays of protein and glucose in human urine samples.

Authors:  Ling Lin; Zhaoxin Gao; Huibin Wei; Haifang Li; Feng Wang; Jin-Ming Lin
Journal:  Biomicrofluidics       Date:  2011-08-08       Impact factor: 2.800

2.  Cyclic olefin copolymer based microfluidic devices for biochip applications: Ultraviolet surface grafting using 2-methacryloyloxyethyl phosphorylcholine.

Authors:  Rajeeb K Jena; C Y Yue
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

Review 3.  Paper-based assays for urine analysis.

Authors:  Eric Lepowsky; Fariba Ghaderinezhad; Stephanie Knowlton; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2017-10-17       Impact factor: 2.800

4.  Demonstration and Characterization of Biomolecular Enrichment on Microfluidic Aptamer-Functionalized Surfaces.

Authors:  Thai Huu Nguyen; Renjun Pei; Milan Stojanovic; Qiao Lin
Journal:  Sens Actuators B Chem       Date:  2011-07-05       Impact factor: 7.460

5.  Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.

Authors:  Pamela N Nge; Jayson V Pagaduan; Ming Yu; Adam T Woolley
Journal:  J Chromatogr A       Date:  2012-09-01       Impact factor: 4.759

6.  Use of photopatterned porous polymer monoliths as passive micromixers to enhance mixing efficiency for on-chip labeling reactions.

Authors:  Dieudonne A Mair; Thomas R Schwei; Theresa S Dinio; Frantisek Svec; Jean M J Fréchet
Journal:  Lab Chip       Date:  2009-01-07       Impact factor: 6.799

7.  Collecting peptide release from the brain using porous polymer monolith-based solid phase extraction capillaries.

Authors:  Jamie M Iannacone; Shifang Ren; Nathan G Hatcher; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

8.  Biomonitoring of perfluorinated compounds in a drop of blood.

Authors:  Pan Mao; Daojing Wang
Journal:  Environ Sci Technol       Date:  2015-05-22       Impact factor: 9.028

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.