Christos D Karkos1, Greg McMahon, Guy Fishwick, Kelly Lambert, Ajay Bagga, Mark J McCarthy.
Abstract
Abdominal aortic aneurysm (AAA) repair in the presence of a kidney transplant can be extremely challenging, as it carries significant risks of renal ischemia. Endovascular repair is an attractive option, as it can be performed with little or no impairment of renal arterial flow. We describe the endovascular management of a recurrent AAA in a patient with a functioning renal transplant using a custom-made aorto-uni-iliac device. We discuss the planning and the potential problems of the technique.Entities:
Mesh:
Year: 2006 PMID: 16132381 DOI: 10.1007/s00270-005-0043-y
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740