Literature DB >> 16132173

Direct comparison of magnetic resonance imaging and conductance microcatheter in the evaluation of left ventricular function in mice.

Christoph Jacoby1, Andrei Molojavyi, Ulrich Flögel, Marc W Merx, Zhaoping Ding, Jürgen Schrader.   

Abstract

The aim of the present work was to study the reliability of conductance microcatheter volumetric measurements as compared to magnetic resonance imaging (MRI) in the same set of mice. Mice left ventricular (LV) volumes were monitored under basal conditions and in a hypertrophy model induced by transverse aortic constriction (TAC). Cardiac function was evaluated in isoflurane anesthetized mice (n = 8) by MRI followed by 1.4 F Millar microtip catheter measurements. The second group of mice with TAC-induced cardiac hypertrophy was studied eight weeks after surgery. Reliability of 3D-reconstructed MRI data was confirmed by comparison with autopsy masses (autopsy LV mass = 73.6 +/- 3.4 mg; MRI LV mass = 76.9 +/- 3.7 mg). Conduction catheter was found to greatly underestimate end-diastolic and end-systolic volumes and thus stroke volume as well as cardiac output in control mice (MRI: EDV = 79 +/- 8 microl, ESV = 27+/-9 microl, SV = 51 +/- 9 microl, CO = 25 +/- 6 ml/min; Catheter: EDV = 28 +/- 5 microl, ESV = 8 +/- 4 microl, SV = 19 +/- 4 microl, CO = 10 +/- 2 ml/min). However, values for ejection fraction showed no significant differences between the two methods. In the hypertrophy model, stroke volume and cardiac output were increased when measured with MRI (SV: +19 +/- 20%; CO: +28 +/- 27%), whereas catheter data showed opposite directional changes (SV: -22 +/- 37%; CO: -31 +/- 37%). Ejection fraction was found to be reduced only in catheter measurements (-31 +/- 26%). In summary, our data demonstrate that absolute volumetric values are strikingly underestimated by conduction catheter measurements and that even detection of directional changes with this method may not always be feasible.

Entities:  

Mesh:

Year:  2005        PMID: 16132173     DOI: 10.1007/s00395-005-0542-7

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  14 in total

Review 1.  Imaging of stem cells using MRI.

Authors:  Dara L Kraitchman; Jeff W M Bulte
Journal:  Basic Res Cardiol       Date:  2008-03       Impact factor: 17.165

2.  Pulmonary regurgitation is a powerful factor influencing QRS duration in patients after surgical repair of tetralogy of Fallot. A magnetic resonance imaging (MRI) study.

Authors:  M Grothoff; B Spors; H Abdul-Khaliq; M Abd El Rahman; V Alexi-Meskishvili; P Lange; R Felix; M Gutberlet
Journal:  Clin Res Cardiol       Date:  2006-10-10       Impact factor: 5.460

Review 3.  Magnetic resonance imaging and spectroscopy of the murine cardiovascular system.

Authors:  Ashwin Akki; Ashish Gupta; Robert G Weiss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-01-04       Impact factor: 4.733

4.  Molecular mechanism of the E99K mutation in cardiac actin (ACTC Gene) that causes apical hypertrophy in man and mouse.

Authors:  Weihua Song; Emma Dyer; Daniel J Stuckey; O'Neal Copeland; Man-Ching Leung; Christopher Bayliss; Andrew Messer; Ross Wilkinson; Jordi Lopez Tremoleda; Michael D Schneider; Sian E Harding; Charles S Redwood; Kieran Clarke; Kristen Nowak; Lorenzo Monserrat; Dominic Wells; Steven B Marston
Journal:  J Biol Chem       Date:  2011-05-26       Impact factor: 5.157

5.  Variability of Mouse Left Ventricular Function Assessment by 11.7 Tesla MRI.

Authors:  Laetitia Vanhoutte; Bernard Gallez; Olivier Feron; Jean-Luc Balligand; Hrag Esfahani; William d'Hoore; Stéphane Moniotte
Journal:  J Cardiovasc Transl Res       Date:  2015-06-13       Impact factor: 4.132

6.  Cardiac mechanoenergetic cost of elevated plasma viscosity after moderate hemodilution.

Authors:  Surapong Chatpun; Pedro Cabrales
Journal:  Biorheology       Date:  2010       Impact factor: 1.875

7.  Cardiac systolic function recovery after hemorrhage determines survivability during shock.

Authors:  Surapong Chatpun; Pedro Cabrales
Journal:  J Trauma       Date:  2011-04

8.  Role of diastolic properties in the transition to failure in a mouse model of the cardiac dilatation.

Authors:  Peter N Costandi; Lawrence R Frank; Andrew D McCulloch; Jeffrey H Omens
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-07-21       Impact factor: 4.733

9.  Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice.

Authors:  Cristian T Badea; Laurence W Hedlund; Julie F Boslego Mackel; Lan Mao; Howard A Rockman; G Allan Johnson
Journal:  Mol Imaging       Date:  2007 Jul-Aug       Impact factor: 4.488

10.  Dynamic correction for parallel conductance, GP, and gain factor, alpha, in invasive murine left ventricular volume measurements.

Authors:  John E Porterfield; Anil T G Kottam; Karthik Raghavan; Daniel Escobedo; James T Jenkins; Erik R Larson; Rodolfo J Treviño; Jonathan W Valvano; John A Pearce; Marc D Feldman
Journal:  J Appl Physiol (1985)       Date:  2009-08-20
View more