Literature DB >> 16131050

Trace metal measurements in low ionic strength synthetic solutions by diffusive gradients in thin films.

Kent W Warnken1, Hao Zhang, William Davison.   

Abstract

In view of conflicting reports regarding the performance of DGT in low ionic strength solutions (I < 1 mM), further investigations have been carried out. Minimal washing of the diffusive gel and deployment in 1.0 and 10 mM NaNO3 solutions containing Cu and Cd gave the theoretical response of 1 for [C](DGT)/[C](SOLN), where [C](DGT) is the concentration of metal measured by DGT and [C](SOLN) is the concentration of metal measured directly in the solution by an appropriate analytical method. Erroneously high values for [C](DGT)/[C](SOLN) were obtained when these same gels were deployed at I = 0.1 mM, presumably due to a net negative charge on the gel, attributable to the presence of initiation products of polymerization. However, washing the diffusive gels completely, where the storage solution pH equaled that of deionized water, gave values of approximately 0.5 for [C](DGT)/[C](SOLN) from deployments at I = 0.1 mM, consistent with the lower measured value of the diffusion coefficients at this ionic strength. These results can be explained by the presence of a net positive charge on the gel when it is exhaustively washed, which reduces the effective diffusion coefficient of metal ions by changing their concentration at the gel-solution interface (Donnan partitioning). Diffusive gel equilibration experiments showed the presence of low capacity sites capable of binding metals irrespective of ionic strength. This binding within the diffusive gel does not affect most DGT measurements, as short (4 h) deployments at concentrations of 10 ppb gave theoretical results. Incomplete washing of the resin-gel caused a 5-15% measurement error and a decrease in precision, even at ionic strengths of 10 mM. A high level of accuracy and precision (typically <5%) was maintained during all aspects of this work, even at ionic strengths of 0.1 mM, in contrast to previous results. This is attributable to three factors: (1) exhaustive washing and conditioning protocols, (2) improvements to the DGT sampling device, and (3) low and reproducible blanks due to ultraclean handling procedures. Provided effective diffusion coefficients measured at the same ionic strength are used, the established DGT theory is obeyed irrespective of ionic strength.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16131050     DOI: 10.1021/ac050045o

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Ferrihydrite containing gel for chemical imaging of labile phosphate species in sediments and soils using diffusive gradients in thin films.

Authors:  Jakob Santner; Thomas Prohaska; Jun Luo; Hao Zhang
Journal:  Anal Chem       Date:  2010-09-15       Impact factor: 6.986

2.  The Gellyfish: An in situ equilibrium-based sampler for determining multiple free metal ion concentrations in marine ecosystems.

Authors:  Zhao Dong; Christopher G Lewis; Robert M Burgess; James P Shine
Journal:  Environ Toxicol Chem       Date:  2015-04-09       Impact factor: 3.742

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.