Literature DB >> 16130666

Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography.

Jan Beens1, Hans-Gerd Janssen, Mohamed Adahchour, Udo A Th Brinkman.   

Abstract

With method development in one-dimensional GC already being a tedious task, developing GC x GC methods is even more laborious. The majority of the present GC x GC applications are derived from previously optimised 1D-GC methods, from which especially the carrier gas flow settings are copied. However, in view of the high pressure inside the first-dimension column (high flow resistance of the narrow-bore second-dimension column), diffusion in the first column is much slower than in 1D-GC. Proper optimisation of the column combination and the carrier gas flow can considerably improve separations in GC x GC. To assist in the process of selecting column dimensions and flow rate optimization, we have developed a computer programme, based on Excel, that enables quick and simple calculation for all types of column combinations. The programme merely needs column dimensions and carrier gas type as input parameters and calculates all resolution and velocity parameters of the GC x GC separation by using flow rate and plate height equations. From the calculations a number of interesting conclusions can be drawn. As an example, the calculations clearly show that the majority of column combinations reported up till now have been operated at a far from optimal flow -- and, consequently, a far from optimal resolution. Probably even more important is the conclusion that the majority of column combinations used so far, i.e. those with 100 microm I.D. second-dimension columns, are not necessarily the best choice for GC x GC.

Mesh:

Year:  2005        PMID: 16130666     DOI: 10.1016/j.chroma.2005.05.086

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes.

Authors:  Nenad D Ristic; Marko R Djokic; Kevin M Van Geem; Guy B Marin
Journal:  J Vis Exp       Date:  2016-08-05       Impact factor: 1.355

2.  Flow-modulated comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry: use of hydrogen as a more sustainable alternative to helium.

Authors:  Micaela Galletta; Mariosimone Zoccali; Nick Jones; Luigi Mondello; Peter Q Tranchida
Journal:  Anal Bioanal Chem       Date:  2022-04-30       Impact factor: 4.478

Review 3.  Naphthenic Acids: Formation, Role in Emulsion Stability, and Recent Advances in Mass Spectrometry-Based Analytical Methods.

Authors:  Roselaine Facanali; Nathália de A Porto; Juliana Crucello; Rogerio M Carvalho; Boniek G Vaz; Leandro W Hantao
Journal:  J Anal Methods Chem       Date:  2021-12-17       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.